 Protection against electrical shock depends on circuit breakers specially matched to the
generating set. If the circuit breakers require replacement, they should be replaced with a circuit
breaker having identical ratings and performances characteristics.
 Due to high mechanical stresses, only tough rubber-sheathed flexible cable (in accordance with
IEC 60245-4) or the equivalent should be used.
 The user shall conform to regulations of electrical safety applicable to the place where the
generating sets are used.
 The user must respect the requirements and precautions in the case of resupply by generating
sets of an installation, depending on existing protective measures in this installation and
applicable regulations.
 Generating sets should only be loaded up to their rated power under the rated ambient
conditions.
 Prior to commencing maintenance work it shall be ensured that untimely start-up is not possible.
Security measures when filling the fuel tank
 The fuel is extremely flammable and poisonous.
 This generator only uses petrol (gasoline); any other kind of fuel will damage the motor.
 Do not overfill the tank with petrol to avoid spilling. If you notice a spill, it must be wiped up
completely with a dry cloth before starting the motor.
 If you swallow fuel by mistake, if you inhale fuel vapours or if you get drops of fuel in your eyes,
see a doctor immediately. If a certain quantity of fuel is spilt on your skin or clothing, wash or
change your clothes.
 Always stop the motor of the generator when filling it with fuel.
 Never fill the fuel tank while smoking or near a naked flame.
 Make sure you don't spill fuel on the motor and the exhaust grille of the generator during filling
with fuel.
 Keep the fuel in an appropriate recipient and sheltered from any sources of fire.
 Carry out filling in a safe place, and slowly open the fuel cap to release the pressure which has
built up inside the tank. Wipe up any drops of petrol that have spilled before starting the motor.
 To prevent fire, move the generator at least 4 meters away from the area for filling with fuel.
 Make sure that the fuel cap is tightly closed before starting.
 Do not keep petrol in the tank for a long time.