Honeywell SmartLine ST 800 User Manual page 37

Pressure transmitters
Table of Contents

Advertisement

PILD Block OS
(Optional)
PILD Block BS
Non-Critical
(Optional)
(continued)
PILD Blockage
(Optional)
<Return>
Current Mode
PILD (Optional)
PILD Factor
Training Result
NOTE: This diagnostics message or PILD sub menu will be visible only if PILD feature is supported by the sensor
and user enabled in the PILD option in the transmitter.
27
OK
BLOCKED
OK
BLOCKED
OK
BLOCKED
Training
Monitoring
PILD factor for
blockage prediction
0.0 to 1.0
SUCCESS
FAILED
ST 800 Pressure Transmitter User's Manual
It is applicable for DP transmitter only.
OK: Blockage is not detected. BLOCKED:
Blockage is detected at one side of impulse
line.
See Note below this table.
It is applicable for DP transmitter only.
OK: Blockage is not detected. BLOCKED:
Blockage is detected at Both sides of
impulse line.
See Note below this table.
It is applicable for AP/GP transmitter only.
OK: Blockage is not detected. BLOCKED:
Blockage is detected at measurement side.
See Note below this table.
Displays the current status of PILD
algorithm i.e., either Training mode or
Monitoring Mode.
See Note below this table
Displays the current PILD factor value. See
the Note below in table.
Displays the training mode result.
Revision 15