Operating Principle; Technical Data - Dimensions - Hydraulic Connections - Ferroli PREXTHERM RSW 92N Instruction For Use, Installation And Assembly

High-effi ciency boiler for liquid or gas fuels
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 25
PREXTHERM RSW N

4.2 Operating principle

PREXTHERM RSW N boilers are fitted with a closed cylindrical furnace, in which the flame produced by the burner is reversed peripherally
toward the front. From there, the burned gas enters the fire tubes. At the outlet, the gas is collected in the smokebox, and is then sent to the
chimney. The combustion chamber is always pressurized during burner operation. For the pressure values, see Table 1, in the column Flue gas
side pressure drop. The flue and flue stack fitting must be made in accordance with current standards and legislation, using rigid pipes that are
resistant to high temperatures, condensate, and mechanical stress, and are airtight.
L1
fig. 1 - 92N÷600N

4.3 Technical data - Dimensions - Hydraulic connections

Key
1
Control panel
2
Burner bracket
3
Smokebox cleaning door
4
Flame inspection window
T1 Central heating feed
fig. 3
T2
Central heating return
T3
Expansion vessel connection
T4
Boiler drain
T5
Flue gas outlet
T6
Burner connection
cod. A73020801 - 2020-11
L1
fig. 2 - 720N÷1060N
EN
27

Advertisement

Table of Contents
loading

Table of Contents