Download Print this page

Technical Details - Conergy PE 245P Instruction Manual

Solar module
Hide thumbs Also See for PE 245P:

Advertisement

Technical Details

The electrical characteristics are within +/-3.0 percent of the indicated value of Pmax and within +/-10.0 percent of the indicated values of VmPP, ImPP, Voc and Isc
under standard test conditions (irradiance of 1000 W/m2, AM 1.5 spectrum and a cell temperature of 25 °C (77 °F)).
Module Type
Maximum
Power (P
PE 245P
245Wp
PE 250P
250Wp
PE 255P
255Wp
PE 260P
260Wp
PE 265P
265Wp
Installation Manual
Maximum Power
Maximum Power
)
Voltage (V
)
Current (I
MPP
MPP
29.59V
29.94V
30.29V
30.63V
30.96V
Conergy
Open Circut
)
Voltage (Voc)
MPP
8.28A
37.50V
8.35A
37.66V
8.42A
37.82V
8.49A
37.98V
8.56A
38.14V
PE 245-265P
Short Circut
Maximum System
Current (Isc)
Voltage (V)
8.86A
1000V
8.92A
1000V
8.98A
1000V
9.04A
1000V
9.10A
1000V
Maximum Series
Fuse Rating (A)
15A
15A
15A
15A
15A