3.
Installation
3.1.

General installation instructions

Make sure that all locally applicable standards, construction regulations and
|
accident prevention regulations are complied with.
The modules must be installed in accordance with National Electrical Code
|
(NEC) in the US and in accordance with CSA C22.1, Safety Standard for
Electrical Installations, Canadian Electrical Code, Part I (CEC) in Canada.
Only use mounting systems recommended by Conergy that can withstand
|
the expected loads for snow, wind, etc. The recommended minimum stand-
off height is 54 mm.
Select an installation location with the maximum sunlight at all times of the
|
year. Avoid shaded areas. Damage to modules can occur when continuously
shaded.
In northern latitudes, orient the solar modules to the south. Deter- mine the
|
ideal setting angle according to the latitude of the installation location.
Request this information from your dealer or find it in the official tables.
Always mount the solar modules with the same orientation and tilt angle.
|
Otherwise special consideration will need to be given to sys- tem design and
inverter selection.
Maintain an adequate distance between adjacent solar modules to allow for
|
expansion in case of changing thermal conditions.
Maintain an adequate distance between the solar module and the mounting
|
surface to ensure sufficient rear ventilation.
The solar modules can be mounted both vertically and horizontally.
|
You can find further installation instructions in the installation manual for the
|
respective mounting system.
The solar modules may be bolted or clamped in place depending on the
|
design of the frame. The mounting system must be made from material that
is resistant to corrosion and atmospheric conditions and able to withstand the
loads required.
Installation Manual
-
Figure 3-1: Dimensions (A), (B), (C)of the solar module; Sizes (1)–(8), positions and
spacings (D), (E), (F), (G), (H) of the mounting holes; Sizes (9) and positions (I) of the
grounding holes; Sizes (K), (L), (N) and spacings (J), (M) of the clamping areas of the
frame corner
Conergy
PE 245-265P
1650 mm
2400 Pa
991 mm
40 mm
,
,
175 mm
,
1300 mm
250 mm
,
,
800 mm
5400 Pa
953 mm
825 mm
,
,
9.0 * 14.0 mm
,
Φ 4.2 mm
,
,
3.
Installation
0 mm
,
412.5 mm
- mm
0 mm
,
247.75 mm
362.5 mm
,
100 mm
100 mm
0 mm
,
247.75 mm
2
2