Trouble Shooting..................... 5. System Drawings....................... 6. Safe Operating Induction Certificate................7. Where to get help....................... 8. Maintenance Checklists....................Conergy Pty Ltd - General Terms and Conditions for Trade..........Limited Product and Power Output Warranty for Solar Modules........Rev 0 - 0704...
1. Introduction Thank you for placing confidence in Conergy and congratulations on the installation of your new Conergy SunEasy grid-connect solar power system, specifically designed for Australian conditions. Conergy SunEasy Grid-Connect solar power system kits have been designed to provide flexibility of use and ease of installation. These kits have been designed to meet the requirements of the current Australian electrical and building codes, including wind loading requirements.
Solar modules produce DC power, usually at 12V or 24V. The inverter included in your Conergy SunEasy solar power system converts DC power to AC power and feeds it into the electricity grid, if not used in your household directly.
Australia and New Zealand. The figures shown are based on the Conergy C175M module outputs. When using Conergy C167P modules the output values will be reduced by approximately 5%.
Conergy SunEasy Grid Connect Kit - User Manual 2.3 Safety The following safety instructions are important for your personal safety and for the optimum performance of your solar power system. Please take the time to go through the following checklist with your installation team. The safety instructions must NOT be ignored.
Page 7
Operational safety Please observe all safety signs installed and all warnings laid out in the accompanying operating instructions. Shut-down procedure The following procedure must be followed to shut down the system, Please refer to the system drawings on page 13): 1.
Page 8
DC disconnecting device DC plugs must never be disconnected from the sockets of the solar modules as long as the Conergy WR unit is feeding power into the mains. Before disconnecting the DC plug you must always disconnect AC power to the inverter.
SunEasy Power system installer so that it can be repaired. 3. System Operation Your Conergy SunEasy solar power system meets all Australian standards and regulations current at the time of installation. All necessary quality-control and safety measures have been observed to guarantee safe and trouble- free operation.
Conergy SunEasy Grid Connect Kit - User Manual 3.2 To Check Systems with the SMA Sunny Boy Inverter 3.2.1 Operating Mode Indication The SMA inverter displays the actual operating status with three LEDs on the inverter lid. Betrieb Operation Erdschluss Earth Fault Störung...
Page 11
Feeding Operation The Sunny Boy has successfully completed the self-test of its electronics components, synchronised to the utility grid and starts Green LED is on feeding generated power to the utility grid. Stop Mode When the green LED blinks 3 times per second, the Sunny Boy is in stop mode.
If none of the above explains the difference, and you are still concerned, call your Conergy SunEasy system installer and ask for assistance to test the inverter and find out how much energy you have generated. Then, if required, contact your electricity retailer and check that their billing system includes energy generated by your solar power system.
Conergy SunEasy Grid Connect Kit - User Manual 8. Maintenance Checklist (We have provided 3 checklists. Please photocopy blanks for following years) Shut down the solar power system before starting work Date: __________________________________ Maintenance by: __________________________________________ Solar panels and array:...
Page 17
Shut down the solar power system before starting work Date: __________________________________ Maintenance by: __________________________________________ Solar panels and array: Bypass diodes verified Panels are clean and free of dust and fungus Array frame securely fixed to roof No visual defects such as fractures, browning, moisture penetration or Array clamps and fastenings tight and secure frame corrosion are present...
Page 18
Conergy SunEasy Grid Connect Kit - User Manual Shut down the solar power system before starting work Date: __________________________________ Maintenance by: __________________________________________ Solar panels and array: Bypass diodes verified Panels are clean and free of dust and fungus Array frame securely fixed to roof...
CONERGY PTY LTD - GENERAL TERMS AND CONDITIONS FOR TRADE Validity of General Terms and Conditions 3.6 C onergy may use payments to satisfy older debts, even if otherwise stated in the Purchaser’s terms and conditions. Conergy will inform 1.1 U ntil Conergy Pty Ltd ABN 57 112 387 569 (“Conergy”) notifies a the Purchaser about any such set-off. In the event that the Purchaser customer of replacement Terms and Conditions, these Terms and has already incurred costs and interest , Conergy will be entitled to Conditions will apply to all sales of products (“Products”) and supplies set-off the payment, first with costs, then with any applicable interest of services (“Services”) by Conergy and will form part of any contract and finally with the principal performance. resulting from any customer (“Purchaser”) placing an order with Conergy except as varied by written agreement by Conergy and the 3.7 T he Purchaser will not cancel or amend any Order accepted by Purchaser (“Order”). Conergy without Conergy’s written approval.
Page 20
Conergy SunEasy Grid Connect Kit - User Manual 6.4 I f within the warranty period applicable to a Product, as set out in Products, or operating performance where such performance Conergy’s product catalogue any new Product sold by Conergy is conditional on empirical factors or on the whole installation is found to be defective in materials or workmanship, or does not or on the individual or overall operation or on the skills of an conform to any applicable drawings and specifications approved by operator), whether made known or not and any liability of Conergy, then Conergy will, at its option, either repair or provide a Conergy to compensate or indemnify any person or persons replacement part or Product provided that: in respect of the foregoing, are expressly negatived and excluded; and 6.4.1 t he Purchaser has given written notice to Conergy of any alleged defect immediately and in any case not later than three 6.12.2 in no event will Conergy be liable for any: (3) days from the date of discovery of the defect; 6.12.2.1 e xpenses incurred by the Purchaser in an attempt to 6.4.2 t he Purchaser has provided Conergy a reasonable opportunity repair or rework any allegedly defective Product or to perform all appropriate tests on the Product; and...
Page 21
Reservation of Title Construction Modifications 11.1 T he Products remain the sole and absolute property of Conergy Conergy reserves the right to modify the construction of Products at any as legal and equitable owner, and the property in and title to the time, however, Conergy is not obliged to carry out such modifications to Products will not pass from Conergy to the Purchaser until the Products already delivered. Purchaser has paid Conergy in full for the Products and for all other Confidentiality Products and Services supplied by Conergy. If not otherwise explicitly agreed, any and all information provided to 11.2 U ntil title in the Products has passed pursuant to clause 11.1 the Conergy in connection with Orders shall not be considered confidential. Purchaser holds the Products as bailee in the capacity of a fiduciary General for Conergy. The Purchaser must keep the Products supplied to it 14.1 I f any of these Terms and Conditions or a provision of any other by Conergy in its possession and take good care of them and store them and mark them in a manner that identifies the Products supplied agreement is held by any competent authority to be unlawful, invalid or unenforceable in whole or in part then the validity of the other and clearly shows that they belong to Conergy. In particular, the provisions of these Terms and Conditions and the remainder of the Purchaser must sufficiently insure the Products at their new value and provisions in question will not be affected and will continue to be valid at the Purchaser’s own expense against fire and water damage and and enforceable to the fullest extent permitted by law.
Conergy must approve any claim in writing. b) For a claim to be made, the original dealer invoice and this warranty certificate should be sent to Conergy or the dealer with details of the module type, the module serial number, the date of delivery and the defects which have arisen.
Need help?
Do you have a question about the SunEasy 1000 and is the answer not in the manual?