Page 1
T-1305 en 22.8.2023 Translation of the original instructions for use Instructions for Use For Automatic Swing Doors with Drive: TORMAX iMotion 1301 Swing Door Drive ® TORMAX iMotion 1301.S Swing Door Drive ® TORMAX iMotion 1302.KI Swing Door Drive ®...
Functional Checks Maintenance and Testing Appendix Fault Table Check-List for Functional Checks Declaration of Conformity First edition: 2.12.11, update: 2.12, 5.21, 8.23 We reserve the right to make technical changes. Instructions for Use TORMAX iMotion 1301/1301.S / 1302.KI /1401 T-1305 en...
Sliding Door TORMAX …………… .HERM System 000/000/00 System No. MM.YYYY DIN 18650-1:2010 Contact Manufactured Max Muster AG DD.MM.YYYY Hauptstrasse 43 – 8049 Zürich Initial SERVICE: 043 827 33 55 Commissioning Instructions for Use TORMAX iMotion 1301/1301.S /1302.KI /1401 T-1305 en...
13,9 kg iMotion 1401 39 kg Control unit: 3,9 kg Noise emission level < 70 db (A) Electromagnetic IEC 61000-6-2, IEC 61000-6-3 compatibility (EMV) Service life Tested to 1’000’000 cycles Instructions for Use TORMAX iMotion 1301/1301.S / 1302.KI /1401 T-1305 en...
• Children must be supervised to ensure that they do not play close to the system and do not operate any available operating controls.. Instructions for Use TORMAX iMotion 1301/1301.S /1302.KI /1401 T-1305 en...
• Only use the system when it is in perfect working order. The operating conditions, inspection and maintenance intervals stipulated by the manufacturer must be observed (chapter 7). • Arrange to have any faults rectified immediately by a specialist. Instructions for Use TORMAX iMotion 1301/1301.S / 1302.KI /1401 T-1305 en...
Danger for body and life, danger of injury • Have system repaired by a qualified person Checks The regular checks and examinations set out in chapter 7 must be carried out as instructed by the manufacturer. Instructions for Use TORMAX iMotion 1301/1301.S /1302.KI /1401 T-1305 en...
• The drives may only be dismantled and prepared for proper disposal by a competent person. Warning Broken glass Risk of injury when dismantling the door leaves. • Take care when transporting the door leaves. Instructions for Use TORMAX iMotion 1301/1301.S / 1302.KI /1401 T-1305 en...
Page 10
£ Depending on the system’s equipment * Provided by the installation company. The company installing the system must select and install suitable components in accordance with the prod- uct standard EN16005 . Instructions for Use TORMAX iMotion 1301/1301.S / 1302.KI /1401 T-1305 en...
Page 11
Battery unit opposite drive side Operating mode switch Safety sensor 3 operating modes Key switch drive side Safety sensor User interface Lock opposite drive side user interface 6 operating modes T1305_14e Instructions for Use TORMAX iMotion 1301/1301.S /1302.KI /1401 T-1305 en...
Double-leaf door systems can also be operated as single leaf doors by means of the single leaf operation switch. In this case both doors can only be opened by means of the key switch or the “passageway for beds” switch. Instructions for Use TORMAX iMotion 1301/1301.S / 1302.KI /1401 T-1305 en...
– Unlocking and opening of the door from outside by means of a key switch and the battery unit u. The closing sequence is maintained in double-leaf door systems by the use of a mechanical door coordinator. Instructions for Use TORMAX iMotion 1301/1301.S /1302.KI /1401 T-1305 en...
4.10 Operating Modes The automatic door system can be operated with the TORMAX user interface u (6 operating modes and status display) or with an operating mode switch u (3 operating modes). Operating Mode OFF The internal and external sensors are disregarded. The door is mechanically held in the closed position and locked using an electric lock u.
Access will be automatically blocked again for 60 s after the button has been pressed for the last time. Selection of Operating Modes • Press selector keys 1 or 2 briefly. The corresponding operating mode symbol is illuminated. Instructions for Use TORMAX iMotion 1301/1301.S /1302.KI /1401 T-1305 en...
• Select operating mode OFF (operating mode switch , user interface ) or disconnect the drive from mains (installation switch, mains plug). • Push the door leaf back into the initial position. • Choose operating mode AUTOMATIC 1 or switch on operator. Instructions for Use TORMAX iMotion 1301/1301.S / 1302.KI /1401 T-1305 en...
If this does not reset the fault or if it re-occurs after a short time, you must arrange for the fault to be rectified by a skilled person from your TORMAX dealer. In this case note the fault number and inform the dealer.
Only genuine TORMAX spare part should be used. The manufacturer accepts no liability if you fail to observe this requirement. Original spare parts and original accessories guarantee the safety of use in accordance with norm EN 16005.
Control system shut down for safety Perform a software-reset. E8.. reasons. The door collides with a – Safety device or setting inadequate. Shut down the system. person. (see chapter 2.7). Instructions for Use TORMAX iMotion 1301/1301.S /1302.KI /1401 T-1305 en...
This leaf then remains open and ary door leaf to close. motionless at about 25 degrees of the door opening until the sec- Secondary leaf ondary door leaf which is closing is practically closed. Instructions for Use TORMAX iMotion 1301/1301.S / 1302.KI /1401 T-1305 en...
Page 21
50 cm of the movement area. Mains Power Cable • Check if the mains power cable is • If damaged, get the mains damaged. power cable replaced by a skilled person. Instructions for Use TORMAX iMotion 1301/1301.S /1302.KI /1401 T-1305 en...
- Declaration of incorporation by TORMAX | LANDERT Group AG - Risk evaluation for automatic swing doors | T-1186 Person responsible for documents Name/address: Place, date: Signatory (CE authorized person): Signature Instructions for Use TORMAX iMotion 1301/1301.S / 1302.KI /1401 T-1305 en...
Page 23
Instructions for Use TORMAX iMotion 1301/1301.S /1302.KI /1401 T-1305 en...
Page 24
TORMAX Folding Door Drives TORMAX Revolving Door Drives Producer Installation company installation repairs , maintenance) TORMAX Unterweg 14 CH-8180 Bülach-Zürich Phone +41 58 500 5000 +41 58 500 5099 www.tormax.com info@tormax.com TORMAX is a division and a registered trademark of LANDERT Group AG...
Need help?
Do you have a question about the iMotion 1401 and is the answer not in the manual?