Tormax 1102 Instructions For Use Manual

Swing door drive

Advertisement

T-1661 e 11.12.20
Translation of the original
instructions for use
Instructions for Use
For Automatic Swing Doors with Drive
TORMAX 1102 Swing Door Drive
TORMAX 1201 Swing Door Drive
Please follow the safety instructions in chapter 2!

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1102 and is the answer not in the manual?

Questions and answers

Summary of Contents for Tormax 1102

  • Page 1 T-1661 e 11.12.20 Translation of the original instructions for use Instructions for Use For Automatic Swing Doors with Drive TORMAX 1102 Swing Door Drive TORMAX 1201 Swing Door Drive Please follow the safety instructions in chapter 2!
  • Page 2: Table Of Contents

    Procedure in the Event of a Fault Maintenance Cleaning Functional Checks Maintenance and Testing Appendix Fault Table Check-List for Functional Checks Declaration of Conformity First edition: 12.14, update 8.15, 11.20 We reserve the right to make technical changes. Instructions for Use TORMAX 1102, 1201 T-1661 e...
  • Page 3: General Information

    1.3 Area of Application Product name, door system: Automatic swing door (single or double-leaf) Product name, door drive: TORMAX 1102 Swing Door Drive / TTX 1102 TORMAX 1201 Swing Door Drive The door drives are defined in more detail by a 4-figure number:...
  • Page 4: Explanation Of The Symbols

    –20 °C to +50 °C Fuse 5 AT Drive weight TORMAX 1102 11,2 kg TORMAX 1201 11,8 kg Noise emission level < 70 db (A), depending on door and substructure Service life Tested to 1’000’000 cycles Instructions for Use TORMAX 1102, 1201 T-1661 e...
  • Page 5: Safety

    (by a specialist) and the measures derived from it. • Structural alterations in the danger area around the door system are prohibited without a new risk assessment (by a specialist) and the measures derived from it. Instructions for Use TORMAX 1102, 1201 T-1661 e...
  • Page 6: Pre-Conditions For The Operation Of The System

    Danger for body and life, danger of injury • Have system repaired by a qualified person Instructions for Use TORMAX 1102, 1201 T-1661 e...
  • Page 7: Checks

    • Before opening the casing, release the tension on the spring up to the stop. Warning Broken glass Risk of injury when dismantling the door leaves. • Take care when transporting the door leaves. Instructions for Use TORMAX 1102, 1201 T-1661 e...
  • Page 8: System Overview

    Double-leaf door system (fig. with standard linkage) 1a,b,d 1a,b,e inside 4a /4b 4a 4b 4c 4d 10c, d 5b 8b outside HK: Main closing edge NK: Secondary closing edge T1661_7e GK: Counter closing edge Instructions for Use TORMAX 1102, 1201 T-1661 e...
  • Page 9 £ Electical lock * £ Depending on the system’s equipment * Provided by the installation company. The company installing the system must select and install suitable components in accordance with the product standard EN16005. Instructions for Use TORMAX 1102, 1201 T-1661 e...
  • Page 10 Sensor safeguarding Drive unit with control system 115 VAC second. closing edge Secondary drive Combined sensor Battery unit inside Switch single leaf Electric door opener/ Combined sensor operation Electric lock outside T1661_15e Instructions for Use TORMAX 1102, 1201 T-1661 e...
  • Page 11: System Functions

    Depending on the configuration, “Power Assist” can be activated in advance for a limited period using a button, door trap sensor or a motion detector. In this case the door can be easily opened with very little effort. Instructions for Use TORMAX 1102, 1201 T-1661 e...
  • Page 12: Traffic Control

    – Unlocking and opening of the door from outside by means of a key switch and the battery unit u. The closing sequence is maintained in double-leaf door systems by the use of a mechanical door coordinator. Instructions for Use TORMAX 1102, 1201 T-1661 e...
  • Page 13: Operating Modes

    4.12 Operating Modes The automatic door system can be operated with the TORMAX user interface u (5 operating modes and status display) or with an operating mode switch u (3 operating modes). Operating Mode OFF The internal and external sensors are disregarded. The door is mechanically held in the closed position and locked using an electric lock u.
  • Page 14: Operation

    Access will be automatically blocked again for 60 s after the button has been pressed for the last time. Selection of Operating Modes • Press selector keys 1 or 2 briefly. The corresponding operating mode symbol is illuminated. Instructions for Use TORMAX 1102, 1201 T-1661 e...
  • Page 15: Setting Customer Parameters With The Tormax User Interface

    The software is restarted. On double-leaf door systems the software is restarted automatically on both drives. 5.3 Setting Customer Parameters with the TORMAX User Interface The company undertaking the installation reserves the right to restrict access to all or some of the customer parameter settings.
  • Page 16: Operation With An Operating Mode Switch

    Parameters for displays Drive type (1 = 1102, 2 = 1201) Firmware version Number of cycles Number of operating hours Control address for network Parameters for settings 10 0…E Hold open time for activator inside / outside 11 0…E Hold-open time button e.g. for beds 0 / 1/ 2 / 3 /4 / 5 / 6 / 8 /10 /12.5 /15 /17.5 /20/40/ 60 s...
  • Page 17: Operation On Power Failure

    If this does not reset the fault or if it re-occurs after a short time, you must arrange for the fault to be rectified by a skilled person from your TORMAX dealer. In this case note the fault number and inform the dealer.
  • Page 18: Maintenance

    Only genuine TORMAX spare part should be used. The manufacturer accepts no liability if you fail to observe this requirement. Original spare parts and original accessories guarantee the safety of use in accordance with norm EN 16005.
  • Page 19: Appendix

    (>1 minute) or defec- range of the sensor(s). tive. The door opens slowly. The safety facility in the opening Remove objects from the sensor direction is permanently active area. (> 1 minute) or defective. Instructions for Use TORMAX 1102, 1201 T-1661 e...
  • Page 20 The door stands still. Control system shut down for Perform a software-reset. E0.. safety reasons. Arrange for the system to be re- E2.. paired by a specialist. Instructions for Use TORMAX 1102, 1201 T-1661 e...
  • Page 21: Check-List For Functional Checks

    This leaf then remains open and ary door leaf to close. motionless at about 25 degrees of the door opening until the second- Secondary leaf ary door leaf which is closing is practically closed. Instructions for Use TORMAX 1102, 1201 T-1661 e...
  • Page 22 50 cm of the movement area. Mains Power Cable • Check if the mains power cable is • If damaged, get the mains pow- damaged. er cable replaced by a skilled person. Instructions for Use TORMAX 1102, 1201 T-1661 e...
  • Page 23: Declaration Of Conformity

    - 2014/30/EU (electro-magnetic-compatibility) and the following harmonised standards have been adhered to: - EN 16005 Base document: - Declaration of incorporation by TORMAX | LANDERT Group AG - Risk evaluation for automatic swing doors | T-1186 Person responsible for documents Name/address:...
  • Page 24 TORMAX Folding Door Drives TORMAX Revolving Door Drives Producer Installation company installation repairs , maintenance) TORMAX Unterweg 14 CH-8180 Bülach-Zürich Phone +41 58 500 5000 +41 58 500 5099 www.tormax.com info@tormax.com TORMAX is a division and a registered trademark of LANDERT Group AG...