Anderson Thermal Solutions –FFA10 Burner Operation Manual However, it is not necessary to purge when the temperature is higher than 750℃. Air pipe or gas pipe connected with burner should be tight enough with no leakage, also the periodically check air or fuel nozzles of the burners to prevent to be blocked by dust, slag or other materials.
Anderson Thermal Solutions –FFA10 Burner Operation Manual 4. Description FFA – FlexFire® Air burner is trademark of Anderson Thermal Solutions (Suzhou) Co., Ltd., it is designed for regenerative glass furnace, with adjustable mechanism for flame length and energy release position.
Page 6
Anderson Thermal Solutions –FFA10 Burner Operation Manual Side port firing b. Under port firing Horizontal adjustment Vertical adjustment Figure 2. FlexFire® burner Adjustment Mechanism Positioning burner bracket Use the positioning tube (sold separately) to locate the bracket. The installation position of the bracket should ensure that the center of the burner nozzle and the sealing plate are coaxial and fit tight without gap.
Anderson Thermal Solutions –FFA10 Burner Operation Manual 5. Prepare for startup Warning Gas line and cooling airline must be equipped with check valves, otherwise flashback may occur! Make sure all gas, cooling air ball valves before burner area closed Confirm that the gas and cooling air have been supplied to the nearest point of burner, where with manual shut-off valves.
Page 8
Anderson Thermal Solutions –FFA10 Burner Operation Manual Before installing the bracket, all position rulers should be checked first, and they should be in the zero position, otherwise, the fixing bolts should be loosened first, and set to zero. Adjust the bracket so that the four fixing bolts are in the middle of the chute to ensure that the bracket can move in all directions.
Page 9
Anderson Thermal Solutions –FFA10 Burner Operation Manual seal plate. If necessary, adjust the height of the bracket to keep the bracket concentric with the burner block. Fix the position of the bracket and remove the positioning tube. Secure the base plate to steel structure.
Anderson Thermal Solutions –FFA10 Burner Operation Manual 7. Start burner Check that the cooling air hose and gas hose are properly and securely connected. After reversal, open the gas manual ball valve on down comer on the firing side. Open the corresponding gas flow control valve to establish the gas flow.
Anderson Thermal Solutions –FFA10 Burner Operation Manual into the inner and outer nozzles changes. Rotating the FDR adjustment to the left (clockwise) will increase the flow of gas in the inner nozzle, the gas velocity will be faster, the flame will be shorter, and the energy release position will move forward.
Anderson Thermal Solutions –FFA10 Burner Operation Manual Clean the seal plate 10.2 Smoky flame Gas rich-reduce gas flow Lean air-increase combustion air flow Debris block the burner tip-take out burner and clean Built-up particles inside burner block-take out burner and clean 10.3 Flame too long...
Page 13
Anderson Thermal Solutions –FFA10 Burner Operation Manual Cautious If the supply of internal cooling air is stopped for more than 20 minutes, to prevent burner being damaged, the burner should be removed and insert the ceramic fiber into the middle of the seal plate.