1,013.25 mbar, 0°C 5. ANM76 Series Burner Description ANM76 series burner is a patented product of Anderson Thermal Solutions (Suzhou) Co., Ltd. This series of linear burners adopts a modular structure design concept and can be configured to match shapes according to site requirements. It is an ideal choice for generating large amount of clean and hot air.
850°C 6. Burner Component Introduction ANM76 series burners are mainly made up of burner body, fire plate as flame shield, diffuser plate. Different parts were connected by rivets, screws and bolts. Shown as below Fig 1 is the diagram of the burner, in which the air wing and outer connectors are made of stainless steel, gas channels and connectors are also stainless steel.
Operation Curve Curve 9. Burner datasheet The input and flame length curves of the ANM76 series burners are shown in Fig 4 and Fig Fig 4. ANM76 Series Burner Input Curve Fig 5. ANM76 Series Burner Flame Length Anderson Thermal Soluions(Suzhou)Co., Ltd...
11. Burner start Special attention: The ANM76 Series burners, described herein, are designed to mix fuel with ai. All fuel burning devices are capable of producing fires and explosions, if improperly applied, installed, adjusted, controlled, or maintained. Do not bypass any safety logics; Never try to light a burner if it shows signs of damage or malfunction.
Anderson Thermal Solutions – ANM76 Burner Operation Manual difference before and after the burner profile plate. Start the combustion air fan, adjust it to 100% of the flow rate, measure the pressure difference between the combustion air and the downstream of the burner, the design DP is 2-2.5 mbar.
Leak detect, control functions of the equipment must be included in the scope of audit. Only Anderson technicians or those who are trained and qualified by Anderson, as well as other relevant professionals, can maintain the burners.
Anderson Thermal Solutions – ANM76 Burner Operation Manual 12.2 Yearly checklist – Leak test the safety shut-off valves and gas train for tightness of closure to make sure no leakage. – Test the pressure switch settings by checking the switch movements against pressure settings and comparing these with the actual pressure.
Anderson Thermal Solutions – ANM76 Burner Operation Manual 14. Appendix 14.1Training Record Each trained person must verify that he has read and understood the contents of the operating manual and know how to operate and maintain this series of burners correctly.
Anderson Thermal Solutions – ANM76 Burner Operation Manual 14.3 Annual Audit Record Yearly audit list as follow but not only included Function Audit Date Inspector Problem description Next Audit Time Leak test Pressure switch test Cable and connectors Burner bodies and air wings Attention:...
Need help?
Do you have a question about the ANM76 and is the answer not in the manual?
Questions and answers