Burner structure refer to Fig 1. Combustion air inlet Installation flange Recuperator Combustion air Spark plug with cooling air inlet backup inlet Exhaust gas outlet Fig 1. Burner parts (Metal recuperator as reference) Anderson Thermal Soluions(Suzhou)Co., Ltd...
Page 5
Table 1 Burner model and capacity Burner Gas Pressure Combustion Air Burner Input Diameter Gas Flow (NCMH) Required @Burner Pressure @Burner Model (mbar) (mbar) Number D (mm) Minimum Maximum Maximum Maximum SRB025 SRB036 SRB060 SRB100 10.0 SRB180 18.0 SRB250 25.0 Anderson Thermal Soluions(Suzhou)Co., Ltd...
Page 6
Once the exhaust gas outlet direction is decided, then the combustion air inlet can be installed at any horizontal or vertical position, refer to Fig 4. The gas inlet can also be adjusted by 45 degrees, refer to Fig 5. Anderson Thermal Soluions(Suzhou)Co., Ltd...
Page 7
Anderson Thermal Solutions – ANM75 Burner Operation Manual Figure 4: Burner air inlet orientation Figure 5: Gas inlet orientation In order to ensure the accuracy of the orifice plate measurement, the burner air and gas inlet positions must ensure that there is a straight pipe section of 5 times the pipe diameter and no other resistance components;...
During the second month, the period between inspections can be extended to two weeks. Anderson recommends that each nozzle is inspected at least once every month. Every time to check the burner, it should be pull out from furnace.
Anderson Thermal Solutions – ANM75 Burner Operation Manual 5.2 Inspection of the recuperator Check if there are any cracks on recuperator during shut down. Need to replace by new recuperator as needed. 5.3 Inspection of the spark plug Check soot or carbon built up on spark, clean as needed.
Anderson Thermal Solutions – ANM75 Burner Operation Manual 7. Appendix 7.1 Training Record Each trained person must verify that he has read and understood the contents of the operating manual and know how to operate and maintain this series of burners correctly.
Anderson Thermal Solutions – ANM75 Burner Operation Manual 7.2 Half Year Audit Record Routine audit must be made every 6 months. Please sign the following table. Function Audit Date Inspector Problem description Next Audit Time Flame sensor state Air and gas pressure...
Page 12
Anderson Thermal Solutions – ANM75 Burner Operation Manual Attention: Safety audit is prohibited when burner is running, otherwise, accident could be caused! If you have any questions. Please call us or send an e-mail to get more information Our telephone no. is +86 (512) 6592 4663...