Page 1
Anderson Thermal Solutions – FFA12 Burner Operation Manual Anderson Thermal Solutions (Suzhou) Co., LTD FFA12 Series Burner Operation Manual No: ATS–Operation Manual–FFA12 Subject:: FFA12 Burner Operation Manual Version : V1.0 Author : Wilson Sun Review : David...
Page 2
Anderson Thermal Solutions – FFA12 Burner Operation Manual CONTENT Disclaimer Notice ............................2 Liability and Warranty ..........................2 Safety instructions ............................2 Description..............................3 Burner data sheet ............................. 4 Installation of the burner ........................4 5. Burner maintenance ............................. 7 Troubleshooting and troubleshooting ....................
Page 3
If the product or its individual modules are used for purposes other than the designated purpose, their effectiveness and suitability must be confirmed. Anderson warrants that the product itself will not infringe any patents. Every effort has been made to make this manual as accurate and complete as possible. If you find errors or omissions, please contact us so we can correct them.
Page 4
The burner system should be checked twice a year for safety operation. 4. Description FFA12 – FlexFire® Air burner is trademark of Anderson Thermal Solutions (Suzhou) Co., Ltd., it is designed for regenerative glass furnace, with adjustable mechanism for flame length and energy release position.
Page 5
Anderson Thermal Solutions – FFA12 Burner Operation Manual Attention! – When the internal cooling air supply stops for more than 20 minutes, remove the burner and seal the seal plate. Prevent burner damage. – External cooling air supply for a long time will cause damage to the sealing plate.
Page 6
Anderson Thermal Solutions – FFA12 Burner Operation Manual Note: the bracket used for side port and under port is difference Side port burner bracket Under port burner bracket Fix the bracket to the steel structure. Install the seal plate to the burner block and tighten it with the retaining bolts.
Page 7
Anderson Thermal Solutions – FFA12 Burner Operation Manual fuel and atomizing air metal hoses to the burner, making sure the connections are correct. Open the atomizing air (adjust it to about 2 bar), slowly open the fuel shutoff valve at burner downcomer until the fuel begins to flow, and adjust the oil flow control valve to obtain the required oil flow.
Page 8
During the first month of operation of the burner, inspection of the nozzle must be carried out every week. During the second month, the period between inspections can be extended to two weeks. Anderson recommends that each nozzle is inspected at least once every month. Every time a burner is left in the furnace 6.