Summary of Contents for Anderson FFAH21

  • Page 1 Anderson Thermal Solutions (Suzhou) Co., LTD FFAH21 Burner Operation Manual No: ATS–Operation Manual–FFAH21 Subject:: FFAH21 Burner Operation Manual Version : V1.0 Author : Wilson Sun David Review :...
  • Page 2: Table Of Contents

    Content Anderson Thermal Solutions – FFAH21 Burner Operation Manual 1. Disclaimer Notice ..........................1 2. Liability and Warranty ........................1 3. Safety instructions .......................... 1 4. Description ............................2 5. Spare parts ............................7 6. Appendix ............................7 Anderson Thermal Soluions(Suzhou)Co., Ltd...
  • Page 3: Disclaimer Notice

    Anderson warrants that the product itself will not infringe any patents. Every effort has been made to make this manual as accurate and complete as possible. If you find errors or omissions, please contact us so we can correct them.
  • Page 4: Description

    4. Description FlexFire® air series burner is a patented product of Anderson Thermal Solutions (Suzhou) Co., Ltd. It is suitable for solid waste incineration, glass melting furnace. FFAH series burner with heated air temperature up to 700°C and flame temperature is up to 2000°C. t is a high-performance burner with independent intellectual property rights, utilizing most up-to-date technology for green fuel combustion, and adjustable mechanism for flame length and energy release position.
  • Page 5 Anderson Thermal Solutions – FFAH21 Burner Operation Manual Attention! – When the internal cooling air supply stops for more than 20 minutes, remove the burner and seal the seal plate. Prevent burner damage. – External cooling air supply for a long time will cause damage to the sealing plate.
  • Page 6 Anderson Thermal Solutions – FFAH21 Burner Operation Manual 4.2 Installation of the burner Inspect burners and burner blocks for obvious damage. Inspect and clean the inside of the block holes to prevent debris from obstructing gas and flames. Fix the burner with four T-bolts corresponding to the four T-slots of the burner block with nuts on the burner block, check whether the center of the burner is aligned with the center line of the block hole, and at the same time, the block and the burner are horizontal due to the overall level.
  • Page 7 4.5 Flame length adjustment FFAH21 burner is mainly composed of preheating combustion air duct and burner body. Hot combustion air enters the burner through the combustion air inlet at a controlled pressure and flow.
  • Page 8 During the first month of burner operation, the nozzles need to be inspected weekly. In the second month, the frequency of inspections can be extended to once every two weeks. Anderson recommends that each nozzle be inspected at least monthly. At each inspection, the burner needs to be removed from the combustion air duct in order to fully check the status of the burner.
  • Page 9: Spare Parts

    Anderson Thermal Solutions – FFAH21 Burner Operation Manual 5. Spare parts With proper use and regular servicing of the burner, we recommend the following parts: Quick Coupler high-temperature gasket Outer nozzle gasket Spare burner nozzle 6. Appendix 6.1 Training protocol Every person who had the training for the burner control system must certify that he or she has read and understood this manual to work on the furnace.
  • Page 10 Anderson Thermal Solutions – FFAH21 Burner Operation Manual Do not carry out maintenance work near the burner when checking the control system If you have any question. Please call us or send e–mail to get more information Our telephone no. is +86 (512) 6592 4663...