Advertisement

Quick Links

Anderson Thermal Solutions (Suzhou) Co., LTD
VFC86 Burner Operation Manual
No:
ATS–Operation Manual–VFC86
Subject::
VFC86 Burner Operation Manual
Version :
V1.0
Author :
Wilson Sun
Review :
David

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VFC86 and is the answer not in the manual?

Questions and answers

Summary of Contents for Anderson VFC86

  • Page 1 Anderson Thermal Solutions (Suzhou) Co., LTD VFC86 Burner Operation Manual No: ATS–Operation Manual–VFC86 Subject:: VFC86 Burner Operation Manual Version : V1.0 Author : Wilson Sun Review : David...
  • Page 2: Table Of Contents

    Anderson Thermal Solutions – VFC86 Burner Operation Manual CONTENT Disclaimer Notice ........................1 Liability And Warranty......................... 1 Safety Guide ..........................1 Fuel Information .......................... 2 VFC86 Series Burner Description ....................2 Burner Component Introduction ....................3 Burner Operation Data ........................ 5 Performance Curves ........................
  • Page 3: Disclaimer Notice

    Loss of or damage to the use of materials that sell, install, use, fail to use or repair or replace Anderson related products.
  • Page 4: Fuel Information

    The burner is also suitable for fresh air operation. VFC86 burner is made up of a frame, flame retaining plate, gas nozzle and gas supply manifold, the sheet metal size 150mmX150mm is fixed in the gas manifold. 8 Slots where cut from the sheet metal, with 2 nozzles symmetrically located in the plate.
  • Page 5: Burner Component Introduction

    750°C. 6. Burner Component Introduction VFC86 burners are mainly made up of frame, flame retaining plate, gas nozzle and gas supply manifold. For different parts, they are connected by rivets or bolts to make up burner body. Burner diagram shown in Fig 1...
  • Page 6 Anderson Thermal Solutions – VFC86 Burner Operation Manual Fig 1 VFC86 Burner Diagram Number Name Number Name Duct Damper Gas channel Upstream pressure test point Downstream pressure test point Pilot burner Side plate Nozzle Air distributes sheet metal VFS86 Series Burner has a separated ignition burner of maximum capacity 50 kW. The user needs to supply combustion air with an oxygen content of 21% for the ignition burner, so, a small air blower or compressed air needs to apply to ignition burner.
  • Page 7: Burner Operation Data

    Anderson Thermal Solutions – VFC86 Burner Operation Manual 7. Burner Operation Data VFC86 burner operation data shown as table 1 below: Table 1 VFC86 Burner Operation data Fresh Combustion air Typical Operation Parameter Content 21%) Condition Model maximum input (kW)
  • Page 8: Burner Installation

    9.4 Burner Mounting 1. Mounting method The installation modes of VFC86 burners are in the duct, the burner surface is vertical to process air, downstream space should be long enough to avoid flame conflict with the duct wall. Provide an opening in the duct 80mm gap on 4 sides of the burne.
  • Page 9: Prepare For Adjustment

    If necessary, the frequency of audit should be increased. Leak detection, control functions of the equipment must be included in the scope of audit. Only Anderson technicians or those who are been trained and qualified by Anderson, as well as other relevant professionals, can maintain the burners.
  • Page 10: Yearly Checklist

    Anderson Thermal Solutions – VFC86 Burner Operation Manual – Test the manual gas shut off cocks for proper operation. 10.2 Yearly checklist – Leak test the safety shut-off valves and pipe for tightness of closure to make sure no leakage.
  • Page 11: Appendix

    Anderson Thermal Solutions – VFC86 Burner Operation Manual 11. Appendix 11.1 Training Record Each trained person must verify that he has read and understood the contents of the operating manual and know how to operate and maintain this series of burners correctly.
  • Page 12: Annual Audit Record

    Anderson Thermal Solutions – VFC86 Burner Operation Manual 11.3 Annual Audit Record Yearly audit list as follow but not only included Function Audit Date Inspector Problem description Next Audit Time Leak test Pressure switch test Cable and connectors Burner bodies and air wings Attention:...

Table of Contents