Recessed Installation - Sears 867.736349 Owner's Manual

Gas.fired forced air wall furnace
Table of Contents

Advertisement

INSTALL VENT SHIELD
The vent shield
is 35-t/8
inches long.
Measure
from
top of furnace
to ceiling.
Cut the vent shield
to this
dimension
less 1/8 inch. Be sure to cut from
the top
(end opposite
flange)
(Fig. 11).
Place vent shield on top of furnace and against the
wall. Drill holes in the furnace top through holes in
vent shield.
Fasten to furnace
with
sheet metal
screws. Screw sides to wall,
install
wood
trim
moulding
if desired,
if 3/4
inch
quarter
round
trim
is used, trim
1/8 inch from
both
side flanges
before
installing
vent shield.
FLANGE
WOOD
TRIM
(NOT
FURN|SHED!
IIIIIIIIIIIIIIIIII
I
II
IIIIIIIIIIIIIIIIIIIIIII
I I
I
llli
IIIIIII
Recessed
Mount
Installation
For ease
of
installation,
servicing
and
cleaning,
install
the furnace
at Least four (4) inches above
the
floor (Fig.
12).
FIND THE STUDS
Use a stud Iocator
or four 8 penny
finishing
nails.
Repeatedly
drive and remove
a nail into the wall in
the area of the stud until it is located. Then find one
side. Leave the nail at this location.
Drive
another
nail just
on the other side of the same stud.
Inside edge of the other
stud should be about 14-1/2
inches
from
the one found.
Drive finishing
nail
on
inside edge of this stud.
CUT WALL OPENING
Lay out and
cut a 14-3/8"
by 74-1/2"
opening
as
shown
in Fig. 12.
WALL LAYOUT
I
14-I/2"
STUDS
/\
!
74-I/2"
t
I
i
|
i 4_
"
:
L
RECOMA_ENDtEO
F J_.'iM.' H. iHJHJ'i
, 11
I
i
LL
Ill
:
9
\

Advertisement

Table of Contents