Sears 867.736349 Owner's Manual page 11

Gas.fired forced air wall furnace
Table of Contents

Advertisement

Remove
two
screws
from
vent
support
assembly
(Fig. 16). Place Base plate
(furnished
with
gas vent
kit) on top of seal.
Fasten
base
plate,
seal,
ftue
collar,
vent
support
and bottom
plate
together
with
screws
(Fig. 15).
VENT SUPPORT
ASSEMBLY
SEAL
FLUE
COLLAR
VENT
SUPPORT
SO'frOM
PLATE
Place the vent
support
between
the studs
with
the
top even with
marks
on the studs (Fig. 15).
Drill pilot holes in the studs through
the two holes in
each side of vent support.
Fasten vent
support
to the studs.
Use four
(4) #10 x
V2" wood
screws
(furnished),
INSTALL FURNACE VENT
Lower a 4 foot length of oval, double wall vent pipe
through the ceiling hole to the base plate. The first
length of pipe must reach from the base plate to at
least 6 inches above the ceiling (Fig. 17). If it does
not, you must use a longer length. Force the vent
pipe into the base plate. Be sure the seal is in place.
Lock the pipe to the base plate with screws furnished
in the B-W gas vent kit.
VENT INSTALLATION
CElUNG
PLATE
SPACERS
6_' MIN.
\
TOP
STORM
COLLAR
ROOF
FLASHING
OVAL
TO
ROUND
ADAPTER
_
CEILING
PLATE
SPACER
LUGS
12 FT, M|N.
/
INSULATION
SEAL
BWVENT
PIPE
VENT
IASE
PLATE
VENT
. SUPPORT
2"'X4"
WALL
STUDS
Install oval to round adapter. Complete
the piping,
extending
it through the roof. Use 4" round, double
wall (Type B-1 vent pi_e, roof flashing,
storm collar
and vent top as shown In Fig. 17. The vent top must
be at least 2 feet above the highest point of the roof
within 10 feet.
There
must
be at
least
1 inch
clearance between the vent pipe and any combus-
tible material.
If an
existing
brick
chimney
is used,
follow
the
directions
above for the section
from the base plate
through the ceiling.
Then you may adapt
to a Type
B-1,4" round,
double wall
pipe for the horizontal
run
to the
chimney.
Connect
into a chimney
only
in
accordance
with
tocai codes and ordinances.
HORIZONTAL
VENT INSTALLATION
The furnace
can be vented
horizontally
only by using
the horizontal
vent kit, Stock No. 42-7369.
On the back wall behind
recess location,
measure
up
71-1/2
inches above
the bottom
of furnace
location
(Fig. 18). Cut an opening
between
the studs 14-3/8
inches
by 10 inches in back wall.