Sears 867.736349 Owner's Manual page 4

Gas.fired forced air wall furnace
Table of Contents

Advertisement

Optional
Accessories
1. Tall Register Kit, Sears Stock No. 42-7312,
For use
when
replacing
a
"Dual
Wail"
furnace.
Tall
register
covers
existing
walt opening.
2. Shot;r Rear
Wall
Register
Kit,
Sears
Stock
No.
42-7313.
For
use
when
installing
two-room
heating
but not replacing
"Dual
Wall"
furnace,
3. Vent
Shield
Kit,
Sears
Stock
No.
42-7311.
is
required
when
mounting
the furnace
on the sur-
face of the wall.
4. Horizontal
Vent
Kit,
Sears
stock
No,
42-7369
is
required
if furnace
;s to be vented
horizontally
into on existing
chimney.
I .
I
IIIIIIIIIII
I II
IIIIIIIIIIIIIJ
I I I
IIIIIIIIIIIII
IIIIIIIIIIIIIIIII
II
IIIII/11]
IIIIIIIIII
I
IIIIIIIllll
IIIIIIII
Furnace Data
MODEL
NUMBER
....867.736349
867.736389
INPUT**
TYPE
RATING
GAS
Btuh***
Nat.
:
65,000
L,P.*
65,000
MAIN BURNER ORIFICE
2 REQUIRED
DRILL
DEC.
...... 36
.1o65"
52
.0655"
PILOT ORIFICE
DECIMAL
.018"
.010"
*Liquefied
Petroleum.
**For
elevations
above 2000 ft. reduce
ratings
4% for each 1000 ft. above
sea level.
***Btuh
= British
Thermal
Units per hour.
BE SURE YOUR FURNACE IS EQUIPPED FOR THE TYPE OF GAS TO BE USED, EITHER NATU_,AL OR L.P. GA,5. THE
CONNECTIONS
FROM THE L.P. BULK STOlYAGE TANK TO THE FURNACE CAN ONLY BE MADE
BY A LICENSED
L.P.
DEALER.
I
......................................................
__..I
"
L
-
Unpack Your Furnace
The shipping
carton
contains
the
furnace
and the
following
items needed
to install
it.
1, Thermostat
and wire
--
packed
inside
lower
cabinet
door (Fig. 1).
2. Top trim
piece and small
parts
bag --
taped
to
inside end of carton.
3. Vent support assembly -- in package taped to
end of furnace.
Store
these
items
where
they
cannot
be lost
or
damaged.
Grasp
each
side of the cabinet
door.
Pull forward
and upward
to remove
(Fig. 1).
BE SURE YOUR FURNACE IS EQUIPPED FOR THE TYPE
OF GAS TO
BE USED, EITHER NATURAL
OR L.P.
CHECK THE RATING PLATE. IT IS ON THE PANEL JUST
ABOVE THE GAS VALVE.
Remove the cabinet
door knob screw.
Reinstall
the
,knob on the outside.
Remove the two (2) screws holding
the upper
panel
(Fig. 1). Remove
the panel for access to fan,
Remove the shipping
bracket
and tape
from the fan
motor.
Untape and remove the spacers
between
the
motor
mount
wires
(Fig. 1).
t' [.</_L_-_
_
\
i
!---=------':
uPPeR
.-
/
/
!
llUlli__
-_
'
SHIPPING
BRACKET
_
r
SHIPPING
RUNNER
CABINET
- -
SHIPPING
RUNNER
_---,._._.
CABINET
DOOR
"
SELECTOt_
SWITCH
KNOB
Reinstall
the upper front
panel,
Stand
the
furnace
upright.
Remove
the runners
(Fig. 1).
Place the selector
switch
knob (shipped
in parts
bag)
on the shaft
sticking
through
the front
panel
(Fig. t).
4

Advertisement

Table of Contents