SURFACE MOUNT
INSTALLATION
(CONTINUED)
install
ovat to round
adopter.
Complefe
the piping,
extending
it through the roof.
Use 4" round,
double
wall (Type B-l) vent pipe,
roof flashing,
storm collar,
and vent top as shown in Fig. 6. The vent top must be
at least 2 feet
above
the highest
point
of the roof
within
10 feet,
There
must
be
at
least
1 inch
clearance
between
the vent pipe and any combusti-
ble material.
If an existing
brick
chimney is used, follow the
directions above for the section from the base plate
through the ceiling. Then you may adapt to a Type
B-1,4" round, double wall pipe for the horizontal run
to the chimney.
Connect into a chimney
only in
accordance with local codes and ordinances.
HORIZONTAL
VENT INSTALLATION
The furnace can be vented
horizontally
only by using
the horizontal
vent kit, Stock No. 42-7369.
lnstafl top support with flange
facing
down as shown
in Fig. 9. Cut a 14-3/8
inch wide by 8l/2 inch hole in
front wal! above top support. Make
bottom edge of
hate even with top edge of top support.
•HOLE
IN
II,ACK
WALL
TOP
SUPPORT
Ii
i I
I i
I I
i
BOTTOM
i
SUPPORT
I
I
1
I
I
I
t
I
n
I
I
I
HOLE IN
FRONT
WALL
Remove the round
knockout
from wall
shield in the
horizontal
vent
kit.
Insert
the wall
shield
into
the
81/2"x14-3/8"
opening
so
that
round
hole
faces
chimney.
Use hole in wall shield
to mark opening
to
be cut in back wall for vent
pipe. If walt
is less than
3-7/8
inches,
trim shield
so front edge
is flush
with
wail
covering.
Cut round
hole.
Nail wall
shield
to
studs
(Fig. 10).
HORIZONTAL
VENTING
BACK
WALL
VENT
SH_LD
TEE
NAIL
TO
Remove the plate, flue collar
and insulation
seat
from the vent support assembly furnished with the
furnace (Fig. 8). Install these with the Tee to 'the top
support as shown in Fig. 10. Discard vent support.
Complete the vent from the Tee to the chimney,
using S" Type B-t vent pipe.
The horizontal
run
should slope upward 1/4" per foot of run. Keep at
least one inch clearance between the vent pipe and
any combustibJe material.
Make sure that the end of the vent pipe does not go
into the chimney
further than the inner surface. Seal
it in place with
furnace
cement.
MOUNT
FURNACE ON SUPPORTS
Hold the furnace
at a sIight
angle
with
top toward
wall.
Insert
the
flue
in
the
openings
in the
top
support
and flue collar.
Straighten
the furnace
by
bringing
it to rest onthe
bottom
support.
Install cabinet
door and front panel.
8