Sears 867.736349 Owner's Manual page 16

Gas.fired forced air wall furnace
Table of Contents

Advertisement

KNOB
,GAS
CONTROL
GA$ COCK POSIT|ON
PILOT
INDICATOR
ADJUSTING
SCREW
COVER
t,
Remove
the screw cover
over the pilot
adjusting
screw
(Fig. 26).
2. Insert a small screwdriver
and adjust flame as
needed.
Turn screw clockwise
(--_)to
decrease
flame.
Turn counterclockwise
(---):to
increase
flame.
3. Turn
the
thermostat
to its highest
setting.
The
main
burner
should
light quickly
and smoothly.
Turn the
thermostat
to its lowest
setting.
Main
burner
shoutd
go out. Pilot should
remain
lit.
4. Replace
the pilot adjusting
screw
cover,
CHECK GAS INPUT AND PRESSURES
Push Hi-Lo knob on gas valve down (Fig. 26). This
sets pressure for highest firing rate.
Gas input to the burners must not exceed the rated
input shown on the rating plate below the burner.
Gas manifold
pressure with the burner on high fire
must be as shown on the rating plate.
Gas supply pressure must be at least 5" water
column for Natural gas and 11" water column for L.P.
gas. it must not be more than 14" water column for
Natural gas or LP gas.
,MAIN BURNER ADJUSTMENT
[I-LO
NOB
I
These points must be checked by a qualified service
technician.
He
should
make
any
changes
or
adjustments
necessary.
Failure to have this done
cou!d
result
in
premature
furnace
failure,
or
unsatisfactory
or possibly hazardous furnace oper-
ation.
ADJUST AIR FOR BURNERS
When the furnace is lighted the first time, the air to
each burner
will
have to be adjusted,
A proper
setting of the air shutter (Fig. 28) gives a soft, blue
flame with no yellow tips.
1. Set thermostat
to highest setting.
2. Loosen the wing screw that holds the air shutter
(Fig. 28).
3. Turn the air shutter counterclockwise
((-',) until
the flame has yellow tips. Turn clockwise
(,-J)until
the yellow tips just disappear (Fig. 27).
4 . Tighten wing screw to hold the shutter in place.
AIR SHUTTER
ROTATE AIR SHUTTER
IN ORDER
TO GET PROPER AIR MIXTURE
/
IMPROPER
FLAME
PROPER
FLAME
ADJUSTMENT
ADJUSTMENT
CHECK THERMOSTAT
Check
the
thermostat,
when
it
is
set
above
temperature
shown on the thermometer,
furnace
burner should light. Be sure the thermostat
turns off
the furnace
when room temperature
reaches the
selected setting and starts the furnace when room
temperature
falls a few degrees.
Set the thermostat for the desired temperature.
CORRECT
JmIIIAIIJlI|IA
IIAdAdlAIAIAAI
/a_u. uuuuuuuuuuuuuu °uuuuuuuu uu 5
1t
AI
II!
I
BtlB•
• II ll_
_
• It
| I
|JILL1
_,__. u uu uu,uu, u
u_u
uu uu u u ,uuu,_uuuu D_.,)
TOO MUCH
AIR,
CONES
BRIGHT
INNER
CONES LIGHT
BLUE POINTED
TOP
OUTER MANTLE
LIGHT BLUE
PROPER FLAME
'l/2"
TO _1/4" HIGH
BLUE AND REAL SHARP
POINTS
INSUFFICIENT
AIR --
LON_
OPEN
END CONES,
YELLOW
IN COt.OR
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

867.736389

Table of Contents