REAR WALL CUT-OUT
.........
T
74.V="
FRONT"
WALL
CUT
OUT
I'
10"
,q
J
7 I- V_" ON
REAR WALL
......
,.-I
I
I
!
I
4" RECOMMENDED
Measure
up 73 inches from top of the support block.
Place a mark on eoch stud at this distance
(Fig. "19).
•VENT TEE AND SHIELD
Screw the BW type Tee from the vent kit to the vent
support assembly
provided with the furnace.
Put the
round opening
in Tee toward
back of vent support
(Fig. 19). Use s crews in vent support (Fig. 16).
Fasten the wall shield to the vent support with four
#10xV=" screws as shown in Fig. 19. The open side of
wall shield must face chimney.
Screws are in parts
bag in vent kit.
Place
the assembled
vent
support,
Tee and
wall
shield through the 10" x 14-3/8"
opening in back wall
(Fig. 20).
Be sure the top of the vent
support
is even with the
marks
on the 2 x 4 studs (Fig.
19).
Drill pilot holes in the studs through
the two holes in
each side of vent support.
Fasten
vent support
to the studs.
Use four (4) #10 x
V2" wood
screws
(furnished).
Nail wall
shield
to studs (Fig. 20).
HORIZONTAL
VENTING
BACK
WALL
WALL
SHIELD
NAIL
TO
STUDS
VENT
SUPPORT
71 -V="
TO BOTTOM
OF FURNACE
Complete
the vent from the Tee to the chimney.
Use
5" Type
B-1 vent
pipe.
Keep
at
least
one
inch
clearance
between
the vent pipe and any combusti-
ble material.
The horizontal
run should be as short as possible
and
should slope upward
1/4" per foot of run,
Make
sure that the end of the vent pipe does not go
into the chimney
further
than the inner surface.
Seal
it in place with
furnace
cement.