Operation; Control Panel Operation; Menu Map; Dmx Configuration - Chauvet DJ Cumulus HP User Manual

Hide thumbs Also See for Cumulus HP:
Table of Contents

Advertisement

4. Operation

Control Panel Operation

To access the control panel functions, use the four buttons located underneath the display. Please refer to
the
Product Overview
to see the button locations on the control panel.
Button
Function
<MENU>
Press to enter the menu and cycle through menu options
When in the menu, press to select a higher value
<UP/TIMER>
When on the main screen, press to activate timer mode
<DOWN/
When in the menu, press to select a lower value
VOLUME>
When on the main screen, press to begin fog output (jumps to Volume Out in the menu)
<ENTER/
Press to return to the main screen
STOP>
When the product is putting out fog or in timer mode, press to stop fog output

Menu Map

Refer to the Cumulus HP product page on
Main Menu
Programming Level Description
Interval Set
Duration Set
Timer Out
Volume Out
Fan Speed
No Water Tips
DMX512 Address
Wireless Set
Direct Timer
Auto Water

DMX Configuration

The Cumulus HP works with a DMX controller. Information about DMX is in the Chauvet DMX Primer,
which is available from the Chauvet website chauvetlighting.com/downloads/DMX_Primer_rev05_WO.pdf.

Starting Address

The Cumulus HP uses 2 DMX channels, which defines the highest recommended address to 511.
When selecting a starting DMX address, always consider the number of DMX channels the DMX mode
uses. If the starting address is set too high, access to some channels could be restricted.
For information about the DMX protocol, download the DMX Primer from www.chauvetdj.com.
To select the starting address, do the following:
1. Press <MENU> repeatedly until DMX512 Address shows on the display.
2. Use <UP/TIMER> or <DOWN/VOLUME> to select the starting address, from 1–512.
3. Press <ENTER/STOP> to return to the main screen.

DMX Channel Assignments and Values

Channel Function
Fan speed
1
(when Ch. 2 is 011  255)
2
Fog output
9
www.chauvetdj.com
5–600S
Sets the output interval in timer mode
5–600S
Sets the duration of fog output in timer mode
1–100%
Sets the output volume in timer mode
1–100%
Sets the output volume in manual mode
1–100%
Sets the fan speed for fog output
ON
Enables/disables "NO Water!" warning
OFF
1–512
Selects the DMX starting address
ON
Enables/disables wireless remote
OFF
NO
Disables/enables timer mode
YES
ON
Enables/disables automatic water pump from the water inlet
OFF
Value
000  255 1–100%
000  010 No function
011  255 1–100%
for the latest menu map.
Percent/Setting
Cumulus HP User Manual Rev. 1
Operation

Advertisement

Table of Contents
loading

Table of Contents