Installation Manual; Selecting The Installation Place - Beko BFYTI 360 Installation Manual

Floor standing air conditioner
Table of Contents

Advertisement

Available languages

Available languages

12

Installation manual

12.1 Selecting the installation
place
12.1.1 Indoor unit
• Install the indoor unit on a strong wall that is
not subject to vibrations.
• The inlet and outlet ports should not be
obstructed: the air should be able to blow all
over the room.
• Do not install the unit near a source of heat,
steam, or flammable gas.
• Install the unit near an electric socket or
private circuit.
• Do not install the unit where it will be exposed
to direct sunlight.
• Select a site where the condensed water can
be easily drained out, and where it is easily
connected to outdoor unit.
• Check the machine operation regularly and
reserve the necessary spaces as shown in the
picture.
• Select a place where the filter can be easily
taken out.
34 / EN
12.1.2 Outdoor unit
• Do not install the outdoor unit near sources of
heat, steam or flammable gas.
• Do not install the unit in too windy or dusty
places.
• Do not install the unit where people often
pass. Select a place where the air discharge
and operating sound will not disturb the
neighbours.
• Avoid installing the unit where it will be
exposed to direct sunlight (other wise use
a protection, if necessary, that should not
interfere with the air flow).
• Reserve the spaces as shown in the picture for
the air to circulate freely.
• Install the outdoor unit in a safe and solid
place.
• If the outdoor unit is subject to vibration, place
rubber gaskets onto the feet of the unit.
minimum space to be reserved (mm) showing
in the picture
Floor standing air conditioner / Installation Manual