33. Mount the inlet cover M63 on the inlet ASSY, using the two screws SRW27.
34. Stick the gasket M20 to the inlet cover.
SRW26
M63
M20
35. * For PX-50XM1
Attach one each of the ferrite cores FL30 and FL31 to the blue and brown
cables of the inlet ASSY.
In addition, attach a green cable (GND) to each of the two ferrite cores FL32
and FL34; each cable wound by two turns.
* For PX-50XM1A,G
Bundle three cables (each in blue, brown, and green) of the inlet ASSY and
mount one each of the ferrite cores FL30 and FL31.
In addition, attach a green cable (GND) to each of the two ferrite cores FL32
and FL34; each cable wound by two turns.
(Caution) These two ferrite cores A are purchased from a parts manufacturer
under the condition that they are already mounted on the inlet
36. Mount the GND terminal of the inlet ASSY by means of the screw SRW26.
FL30,31
SRW27 x 2
FL32,34
GND
PX-50XM1
ASSY.
FL30,31
FL32,34
A
GND
SRW2
PX-50XM1A,G,GS
11