31. Stick the filament tape C (15
x 10mm) [P/N 92203967] to
Corner B of the inlet mount-
ing part A, just like the tape
covers this portion.
32. Put the barrier M09 on the
inlet ASSY E02, and mount
it by means of the two
screws SRW25.
(Caution)
The barrier shall be posi-
tioned so that its bent part
faces upwards.
M63
33. Mount the inlet cover M63
on the inlet ASSY, using
the two screws SRW03.
M20
34. Stick the gasket M20 to the
inlet cover.
C
E02
B
SRW25 x 2
M09
A
SRW03 x 2
TOP
10