UNI-T UDP6722 User Manual page 18

Programmable dc power supply
Table of Contents

Advertisement

User's Manual
<List Setup>
Item
FileNum
Start
Group
Repeat
Finish
Enable
Sheet
Memory
Press [Sheet] key to enter Sheet setup.
Instruments.uni-trend.com
Setting
Description
The currently loading list file, press [Save] shortcut key to
/
enter <ListFile> to save and recall the file.
Select the line to start the test from the list on the right side,
0-199
the default is 0.
Count the output step starts from the initial group number,
1-199
the default is 1.
1-9999
Times of test cycly, the default is 1.
Stop: stop the output when the test is finished.
Stop, Hold
Hold: output the last test item when the test is finished.
Whether to enable the list test, if the list test is enabled, LIST
displays in title bar.
After the list test is enabled, press [On/Off] key to start the list
Off, On
test and the indicator will blinking to distinguish from the
normal output.
Enable the list test will turn off the delayer function.
/
Enter sheet set up
/
Enter Memory (Local and USB)
UDP6722 Programmable DC Power Supply
18 / 32