Remote Sensing - UNI-T UDP6722 User Manual

Programmable dc power supply
Table of Contents

Advertisement

User's Manual

5.8 Remote Sensing

When the power output current is too large or the connecting line is too long, a large voltage drop will be
generated on the connection line, resulting in a decrease in the voltage obtained by the load. This series
provides a remote compensation terminal on the rear panel, which can compensate for the line loss of the
connecting line, so that the voltage at the load end is equal to the voltage set by the power supply.
5.8.1 Wiring of Remote Sensing
1.
2. Remove the shortcircuit plate between Vs+ and Vo+ and Vs- and Vo-.
3. Use the output terminal on the front panel or Vo+ and Vo- on the rear panel to connect to
4. Use Vs+ on the rear panel to connect the positive end of the load, Vs- connect to the
Notes
1.
It would be better to strand Vs+ and Vs- together to enhance the anti-interference capability.
2.
If not use remote sensing, please separately short connect Vs+ and Vo+, Vs- and Vo-.
Instruments.uni-trend.com
Figure 5-5 Remote Compensation on Rear Panel
Turn off the output of power.
the load.
negative end of the load.
Figure 5-6 Wiring of Remote Sensing