7. Product Specifications

T e c h n i c a l d a t a
Output power
Input voltage
Input frequency
Output voltage
Output frequency
Charging time
UPS Classification / Wave form
Protection
Transfer time
Back up time
Interface
Safety / EMC
Temperature
Humidity
Dimensions
Weight (net)
Product-specific data
Transfer limit in mains / UPS mode
Transfer limit into UPS mode
in case of overvoltage at the input
Type of battery
Noise development
Load sensor
Button
The service life of the batteries is app. 4...5 years at +20 °C and will decrease by half with each temperature increase of 10 °C according to EUROBAT.
During storage the UPS has to be charged at least every 6 months.
24
400 VA / 240 W
230 V AC ±15 %
50 / 60 Hz ±5 %
230 V AC ±15 %
50 / 60 Hz ±1 %
App. 8 h (90 % load)
VFD / Rectangular
Overload protection: UPS mode: 100...120 %, Alarm
Mains mode: Fuse
Overtemperature protection: Switch off
<6 ms
100 W / 166 VA load
180 W / 300 VA load
USB
EN62040-1-1, CE, EN62040-2
Operating: 0...+40 °C / Storage: 0...+40 °C
Operating: 10...85 %, non-condensing
Storage: 10...90 %, non-condensing
146 x 253 x 42 mm ±0.5 mm
2.75 kg
190 V AC ±5 %
248 V AC ±5 %
2 x 6 V / 3 Ah maintenance-free lead-gel batteries (VRLA)
<35 dbA
≤33 W*
To switch off alarm sound press for app 1 sec.
To switch off UPS press for app 4 sec.
To switch on UPS (cold start, without mains supply)
press for app 2 sec.
User's Manual IUPS-401-B8
120...190 %, Switch off
app. 5 min
app. 2...3 min