Power distribution protection systems
Mains inrush current limiting (soft start and anti-surge).
Mains average current limiting (mains breaker / fuse trip protection).
Randomised initialisation when powered up to reduce the peak power demand in large systems.
Monitoring and logging
Supply current logged vs time
Supply voltage logged vs time
Thermal Capacity logged vs time
Each driver current logged vs time
Each driver impedance logged vs time
Protection limiting for each output logged vs time
An inbuilt alarm and notification system can be configured to indicate problems to remote devices either via the network or
the Volt-free changeover relay contacts accessibly on the rear panel.
Physical
Cooling
Airflow
Air filtration
Analog IN and LINK connectors
AES3 IN and LINK connectors
Audio output connector
Mains input connector
Dante Primary and Secondary
Relay output & contact closure inputs/output
LED indicators
Enclosure
Depth (behind rack ears)
Net Weight
Options
There is internal provision for digital audio network option cards to be factory fitted. Currently EM
Acoustics support Dante from Audinate.
Rear rack support kit (part number ZA1182).
Number of power cycles counted
Number of mains brownout events counted
Fan speeds continuously monitored
Fan underspeed events counted
Various protection mute events counted
Driver Impedance continuously monitored
Variable speed fans.
Front to back.
Washable media, changeable without the use of
tools.
Genuine Neutrik XLR.
Genuine Neutrik XLR.
Genuine Neutrik Speakon.
Genuine Neutrik 32A Powercon.
Shielded RJ45.
Phoenix pluggable terminal blocks.
Bright, easily differentiated.
Standard 19" 2U (88mm) with handles and optional
rear support system
357mm (14").
12.5kg (27.5 pounds).