Take an Ethernet cable and connect one end to the LMU-5541™ RJ-45 connector and the other end to the maintenance computer.
Launch the terminal emulation program.
Power up the LMU-5541™.
Type: AT#ESN? <Enter>
Write down the ESN of the unit.
Remove power from the LMU-5541™.

8.3 Maintenance computer network setup

Change the IP settings on the maintenance computer to match the subnet of the LMU-5541™
Go to Control Panel → Network and Internet → Network and Sharing Center → Change adaptor settings → Local Area Connection → Properties → Internet
Protocol Version 4 (TCP/IPv4) → Properties →
Select "Use the following IP address:"
Enter the following IP settings:
Ethernet IP address = 192.168.1.189
Subnet mask = 255.255.255.0
Default gateway = 192.168.1.55
Ensure WiFi is disabled on the maintenance computer.

8.4 Programming the IMX processor

Apply power to the LMU-5541™, then view the terminal emulation screen.
Enter <B> to break the u-boot.
Net: FEC [PRIME]
Normal Boot
Hit 'B' to stop autoboot: 0
LMU5541-Boot >
The command prompt "LMU-5541-Boot >" will appear.
Type: nand erase.chip <enter>
LMU5541-Boot > nand erase.chip
https://puls.calamp.com/wiki/LMU-5541_Hardware_%26_Installation_Guide
LMU-5541 Hardware & Installation Guide - PULS Wiki
Select OK