MITER ALIGNMENT

Your saw is calibrated at the factory to cut true. Over time the
saw's calibration may drift and will need to be re-calibrated.
See Figure 13.
1.
Unplug the Saw.
2.
Lower the saw head all the way down to the transport
position and engage the saw head lock pin
it in place. Push the saw head into the fully retracted
position and engage the slide lock lever
place.
3.
Set the miter position to 0° and allow the miter detent
button
to lock into position.
F28
4.
Set the bevel position to 0°. Engage the bevel detent
latch
to lock bevel angle.
F21
5.
Place a framing square
face of the saw blade.
NOTE: Make sure the square contacts the flat part of the blade
and not the teeth.
See Figure 14.
6.
If the blade face is not flush with the square you will
need to adjust the miter scale
7.
Loosen the four screws
adjust the miter scale position. Set so the fence and
blade are flush against the framing square. Make sure
the miter lock knob is not locked, so the miter scale may
be adjusted.
8.
Re-tighten the four screws and re-check the miter scale
alignment.
NOTE: After squaring adjustments have been made, it may be
necessary to loosen the indicator screws
to zero.
ADJUSTMENTS
to hold
F20
to hold it in
F31
against the fence and the
A
.
B
and move the miter table to
C
and reset them
D
F31
F20
F21
A
B
Figure 13
D