Operational Problems; List Of Alarm Messages - Sony SVO-5800 Operating Instructions Manual

Videocassette recorder/player
Table of Contents

Advertisement

Operational Problems
This section describes the alarm messages which indicate misoperations or
problems with the unit and what to do in such cases. Check this section before
consulting your Sony service representative.
Alarm Messages
There are a number of messages which may appear on the monitor screen during
operation.
Example of alarm message
*R00°00
00:00
Alarm message
These alarm messages indicate misoperations or problems with the unit, such as
condensation on the drum. Check the following table in such cases.
To display these messages on the monitor screen, the monitor must be connected to
the MONITOR VIDEO connector, and the CHARA. DISPLAY item of the
DISPLAY CONTROL menu must be set to ON (page 45(E)).
List of alarm messages
The alarm messages which are likely to be displayed are as listed below.
Alarm messages on the
Meaning of alarm
What to do
monitor screen
HUMID
Condensation" has been detected.
Cassette is ejected automatically. Keepthe
power on and wait until this message
disappears.
NOT TC/UB SELECT!
CTL mode is selected.
Set the CTL/TC/U-BIT selector to TC or U-
NOT UBG PRESET!
NOT INTERNAL!
Set the EXT/INT switch to INT.
1) Condensation: If the unit is suddenly moved from a
cold to a warm location, or used in a hot room,
moisture from the air can condense on the head
drum. This is called condensation, and if the tape
runs in this condition, the tape may stick to the
drum, in which case it is highly likely to be
damaged.
Operational Problos
Operational
Problems
WIALNHUI
97(E)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Svo-5800pSvp-5600Svp-5600p

Table of Contents