ECD M.O.L.E. EV20 Quick Reference Manual page 21

Table of Contents

Advertisement

7.
As the M.O.L.E. thermal profiler and test product
emerge from the process, retrieve the sensors
from the test product and lay the thermal barrier
on a table or flat surface.
8.
Open the thermal barrier and if the Record
button is still flashing this means the M.O.L.E.
thermal profiler is still logging and it should be
stopped.
9.
Remove the M.O.L.E. thermal profiler from the
thermal barrier and wait a few minutes for it to
cool. Handle it carefully, as the case may still be
warm.
10.
Disconnect M.O.L.E. thermal profiler from the
sensors and place it near the PC that has MAP
installed.
If sensors are removed before the M.O.L.E.
thermal profiler has stopped collecting data, it
may cause the data to become distorted.
OPeRATiOn
dOWnLOAd dATA
20