Hub Input Power
The Hub requires a constant 230 VAC (required if using actuators) or 115 VAC input power to oper-
ate. A wiring harness is included and will plug into the input power connector shown on page 10.
Wire the harness according to the diagram below.
For easy installation, if replacing an existing 230 VAC pump, disconnect power at the pump and use
that connection to provide power to both the Hub and the new variable speed pump (VSP). Use the
included Wiring Whip to aid in this connection. The diagram below shows an existing timeclock used
to power the old pump. This configuration can be easily modified to power the VS Omni and the new
VSP. Refer to the diagrams below.
Existing Timeclock
Disconnect from existing
230 VAC pump
Connect to Hub and
new Variable Speed
Pump (VSP)
11
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
High Voltage Wiring
N
L1
115 VAC
L2
L1
230 VAC
230 VAC
L2
L1
Ground
Wiring Whip to
VSP