J35 OPERATIONAL STATUS INDICATOR

The following details the operational status of the J35, as shown by the coloured
flash of the LED Status Indicator on the J35.
STATUS
Internal Error
Identify Device
Storage Mode
AC, Charging Normally
AC, Low Battery Voltage
AC Connected, No Battery
(J35B-L and J35D only)
Solar, Charging Normally
Aux, Charging Normally
AC, Battery OK or No
Battery
Solar, Battery OK
Aux, Battery OK
Normal, No source present
One (or more) Output is
Overloaded
Critical Fault
Solar Fault
Battery Fault
Over Voltage Fault, or High
Temperature Fault
OFF
J35 Powered Off
COLOUR CODE
FLASHING STATUS
On, Solid
Flashes, 5 Times Quickly
Flashes Every 2min
On, Solid
Flashes, 1 Time
Flashes, 1 Time
Flashes, 2 Times Quickly
Flashes, 3 Times Quickly
On, Solid
Flashes, 2 Times Quickly
Flashes, 3 Times Quickly
Flashes, 1 Time
On, Solid
Flashes, 4 Times Quickly
Flashes, 3 Times Quickly
Flashes, 2 Times Quickly
Flashes, 1 Time
Off