FAULT PROTECTION

Overload or Short Circuit Protection
If an overload or short circuit is detected the affected output will shut down. The
J35 will automatically reconnect a faulty output up to 3 times within a 45-second
window. If the fault is still present after the 3rd attempt, the output will be
permanently disabled. Normal operation may resume once the fault has been
rectified and the system is reset.
Over-Voltage or High Internal Temperature Protection
If an overvoltage or high internal temperatures are detected the J35 will
automatically turn off. Once the overvoltage is rectified, or the internal
temperature drops to normal levels, the J35 may be restarted by cycling the
mains input on and off.
Reverse Battery Protection
The J35 battery fuse and fuse fitted by your Jayco dealership at the battery
protects from accidentally connecting the battery to the J35 in reverse polarity.