Problem and alarm code
The temperature of the wa‐
ter inside the appliance is
too high or malfunction of
the temperature sensor oc‐
curred.
The display shows i61 or
i69.
Technical malfunction of
the appliance.
The display shows iC0 or
iC3.
The level of water inside
the appliance is too high.
The display shows iF1.
The appliance stops and
starts more times during
operation.
The programme lasts too
long.
The remaining time in the
display increases and
skips nearly to the end of
the programme duration.
Small leak from the appli‐
ance door.
The appliance door is diffi‐
cult to close.
Rattling or knocking
sounds from the inside of
the appliance.
The appliance trips the cir‐
cuit-beaker.
Possible cause and solution
• Make sure that the temperature of the inlet water
does not exceed 60°C.
• Switch the appliance off and on.
• Switch the appliance off and on.
• Switch the appliance off and on.
• Make sure that the filters are clean.
• Make sure that the outlet hose is installed at the right
height above the floor. Refer to the installation in‐
structions.
• It is normal. It provides optimal cleaning results and
energy savings.
• If the delay start option is set, cancel the delay set‐
ting or wait for the end of the countdown.
• Activating options can increase the programme dura‐
tion.
• This is not a defect. The appliance is working cor‐
rectly.
• The appliance is not levelled. Loosen or tighten the
adjustable feet (if applicable).
• The appliance door is not centred on the tub. Adjust
the rear foot (if applicable).
• The appliance is not levelled. Loosen or tighten the
adjustable feet (if applicable).
• Parts of the tableware are protruding from the bas‐
kets.
• The tableware is not properly arranged in the bas‐
kets. Refer to basket loading leaflet.
• Make sure that the spray arms can rotate freely.
• The amperage is insufficient to supply simultaneous‐
ly all the appliances in use. Check the socket amper‐
age and the capacity of the meter or turn off one of
the appliances in use.
• Internal electrical fault of the appliance. Contact an
Authorised Service Centre.