Checking electrolyte level
Procedure
e
Read off electrolyte level at MIN/MAX
markings.
Note
Use only distilled water for topping up
battery.
Remove filler plugs and screw in with a
coin.
Caution
Battery
acid
is
corrosive
to
metal
or
enamel surfaces.
Before recharging or removing a battery,
always switch off engine and disconnect
the terminals.
Never run the engine without the battery
connected, or else the alternator may be
destroyed.
Check that battery venting hose is routed
correctly, and open.
Warning:
The
battery
contains
sulfuric
acid.
Avoid contact with skin, eyes or cloth-
ing. Antidote:
EXTERNAL-Flush
with
water, INTERNAL-Drink
large quanti-
ties of water or milk.
Follow with milk of magnesia, beaten
egg or vegetable oil.
Call
physician
immediately.
Eyes:
Flush with water and get prompt medi-
cal attention.
Batteries
produce
explosive
gases.
Keep
sparks,
flames
and
cigarettes
away. Always shield eyes when work-
ing near batteries.
KEEP OUT OF REACH OF CHILDREN!
Recharge battery only in a well venti-
lated area.
Filler caps must be tight.
Maintenance instructions
Ifthe motorcycleis not ridden for more
than a month, disconnect battery ter-
minals.
Procedure:
Unscrew the negative cable (1) at the
gear box and insulate it.
Top up distilled water to MAX mark.
Store battery in a cool and dry place.
Check electrolyte level regularly.
Suggestion:
Connect
the
BMW
mo-
torcycle
battery
charger
for
1
day
every 4 weeks
to maintain
optimum
battery life.
Caution
improper treatment of battery invalidates
battery warranty!