Precautions for Selecting a Location

• Before choosing the installation site, obtain user approval.
®1·1·11 1 1 , 11 @
The indoor unit should be positioned in a place where:
1) the restrictions on the installation requirements specified
in "Indoor/Outdoor Installation Diagram" are met.
2) both the air inlet and air outlet are unobstructed,
3) the unit is not exposed to direct sunlight,
4) the unit is away from sources of heat or steam,
5) there is no source of machine oil vapour
(this may shorten the indoor unit service life),
6) cool air is circulated throughout the room,
7) the unit is away from electronic ignition type
fluorescent lamps (inverter or rapid start type) as they
may affect the remote controller range,
8) the unit is at least 1 m away from any television or radio set
(the unit may cause interference with the picture or sound),
9) the unit can be installed at the recommended height (1.8m),
1 0) no laundry equipment is nearby.
Outdoor Unit Installation Space Requirements
it,
CAUTION-------------
When carrying the outdoor unit during installation. wear gloves to avoid injury.
• Position the unit on a horizontal surface.
Any tilt in the unit (front to back. right to left) should be 3' or less to the horizontal.
• Where a wall or other obstacle is in the path of the outdoor unit's
intake or exhaust airflow. follow the installation space requirements below.
• For any of the below installation patterns, the wall height on the
outlet side should be 1200mm or less.
r
I
I
Wall facing one side
More than 350
1200
or less
Side view
Accessories ®~®
Remarks
QTY.
® Remote controller holder fixing screw (M3 x 20L
0
1
<D 4-Core wire (3.7M)
0
6/7·
*
® Tie wrao
0
1
® Accessorv filter
2
® Gas oipe (3.0M)
0
2
(Q) Liquid pipe l3.0Ml
0
1+1
® Drain socket
0
1
*
® Heat insulation tape
0
1
CD Wi-Fi manual
1
The outdoor unit should be positioned in a place where:
1) the restrictions on the installation requirements specified
2) drain water causes no trouble or problem in particular,
3) both air inlet and outlet have clear paths of air
4) the unit is in a clear path of air but not directly exposed
5) there is no fear of inflammable gas leakage,
6) the unit is not directly exposed to salt, sulfidized
7) operating sound or hot airflow does not cause trouble
8) the unit is at least 3m away from any television or
I
I
Walls facing two sides
More than 50
Top view
ITEM
in "Indoor/Outdoor Installation Diagram" are met.
(they should be free of snow in snowy districts),
to rain, strong winds, or direct sunlight,
gases, or machine oil vapour (these may shorten the
service life of the outdoor unit).
to neighbours.
radio antenna.
Viewed from
the front
I
Walls facing three sides
"
c:::)
More than 50
*
Remarks
QTY.
*
2
*
1
*
6
*
112·
*
1
*
1
*
1
*
1
1
Table No.1
Viewed from
the side
I
Jhore than 100
I
More than 350
..(l..
Top view
unit:mm