Donaldson Torit PowerCore CPV-1 Installation And Operation Manual page 14

Hide thumbs Also See for PowerCore CPV-1:
Table of Contents

Advertisement

Donaldson Company, Inc.
Input
105-135V/50 -60Hz/1Ph
Output Solenoids
The load is carried and turned ON and OFF by the 200
watt maximum-load-per-output solid-state switch.
Pulse ON Time
Factory set at 100-milliseconds or 1/10-second.
Do not adjust pulse ON time
unless the proper test equipment
is available. Too much or too little ON time can
cause shortened filter life.
Pulse OFF Time
Factory set at 10-seconds, adjustable from 1 to
180-seconds.
Disconnect
L1
L2
L3
208-230V
60 Hz/3Ph
Wiring by others
Wiring by factory
Disconnect, fuses, low voltage blower starter, and 1TGS switch are customer-supplied.
Use wiring diagram provided with collector
11
Blower Starter
1FU
IL1
1M
1OL
2FU
IL2
3FU
IL3
230V
H3
H1
H2
H4
X1
X2
115V
start
1M
stop
1M
1TGS
Solid-State Timer Typical Wiring Diagram
Operating Temperature Range
-20° F to 130° F
Transient Voltage Protection
50 kW transient volts for 20-millisecond duration once
every 20 seconds, 1% duty cycle.
Solenoid Valves
115-V at 19.7 watts each
Compressed-Air
Set compressed-air supply pressure to a level suitable
for the filters (90-psig). The pulse-cleaning controls are
factory set to clean one or more filters every 10-seconds
during a cleaning cycle.
damage can occur.
OFF time
1T1
fan
1T2
motor
1T3
pressure
switch
power
supply
4FU, 3A
105 to 135 V
50-60 Hz
Do not increase supply pressure
above 100-psig as component
Control Box
ON time
LAST CHANNEL
16 8
4
2
1
LAST CHANNEL SWITCH SETTINGS
32
00000
21
01011
10
10110
31
00001
20
01100
9
10111
30
00010
19
01101
8
11000
29
00011
18
01110
7
11001
28
00100
17
01111
6
11010
27
00101
16
10000
5
11011
26
00110
15
10001
4
11100
25
00111
14
10010
3
11101
24
01000
13
10011
2
111110
23
01001
12
10100
1
111111
22
01010
11
10101
0:OFF
1:ON
timing
logic
control
logic
COM
1
2
L1 L2
solenoid
valves

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PowerCore CPV-1 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents