Fill the salt tank with water. Put a liter of water into the salt tank for each liter of resin contained in the softener
bomb. (Example: 8 liters of water should be added for an 8 lc resin softener). Subsequently, the water will be
loaded fully automatically
Fill 3/4 of the salt container with SALT (salt in PADS is recommended as it has less impurities than coarse salt).

PARAMETERS

For enter on the parameters menù:
Unlock the display, press and hold the button 3 and 4 for 5 seconds
Push the button 1 for entering on the menù
Press keys 3 and 4 to scroll through the parameters, to modify a parameter press key 1. Select the value with
keys 3 and 4, to confirm press key 1
Push the button 2 for exit to the menù
PARAMETERS LIST:
F-00
cod.W010771-rev.1
Time of day
Regeneration time
Regeneration modality
Setting A-01
FOR CORRECT VALVE OPERATION, LEAVE THE SET PARAMETER F-00
Water treatment capacity
phase 2 : backwash time
phase 3 : Brine e slow rinse time
A-01: when the available volume drops to zero,
Pag. 16
00:00 – 23:59
00:00 – 23:59
the regeneration will star until at regeneration
time
A-02: Regenerate immediately when the
available volume drops to zero
0 – 99.99 m3
0 – 99 min.
0 – 99 min.
05/06/2021