Display; Start-Up - Gastrodomus AV8C Installation, Operating And Maintenance Manual

With automatic regeneration
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11

DISPLAY

1
Parameters menù/confirm
2
Manual Regeneration / exit
3
4
5
6
Backwash phase 2
7
Fast rinse phase 5
8
9
Brine refill phase 4

START-UP

When commissioning the appliance it is necessary:
Open the cock supplying the softener.
Open a cock for air inside the ducts bleeds and the resins are washed. The outlet water may, for a few minutes,
be dark coloured. Leave it to run until is "cleaned", before using it.
Check for leaks from the hydraulic connections.
Connect the transformer plug to the specific socket in the rear part of the valve.
When switching on for the first time, wait that the valve goes to the service position, the display indicates "-00-"
Set the time: by pressing key 1 you enter on menù and the first parameter found is the time. To modify it, press
key 1 and choose the hour with keys 3 and 4. Press key 1 to move to the minutes, choose the correct value with
keys 3 and 4. Once finished, press key 1 to confirm, then key 2 to exit programming.
cod.W010771-rev.1
Down button
Up button
Service
Time
WARNING: when the indicator 12 lights on, the buttons are locked
For unlocked, press and hold the button 3 and 4 for 5 seconds
10
Brine e slow rinse phase 3
11
12
13
14
Water treated capacity (m^3)
15
16
17
Pag. 15
Setting
Button lock
Day
M^3/h in service
Regeneration time
Display
05/06/2021

Advertisement

Table of Contents
loading

Table of Contents