INSTALLATION

This instructions manual is an integrating part of the automatic valve for water softening (also defined in this instructions
manual, more simply with the terms of valve or appliance) and must be kept for any future consultation. Carefully read
the warnings contained in this manual before installing and using the valve. These warnings have been drawn up for the
safe installation, use and maintenance; any warnings or diagrams relating to particular models, will be provided attached
to this instructions manual. Any intervention to the electrical system or hydraulic system must be carried out by qualified
and enabled staff only.
Any use of the valve different from the production of softened water, using water at temperatures above 50° is to be
considered improper. To guarantee valve efficiency and for its correct functioning, it is essential to comply with the
Manufacturer indications having installation and repairs carried out by qualified staff, as the intervention of inexperienced
persons, can cause or worsen damages, as well as be dangerous.
We recommend to always pretend original spare parts.
When foreseeing the demolishing of the appliance, it is advised to make it unusable and dispose of it and recover the
materials, in accordance with the relative national dispositions in force.
In order to avoid damaging the valve, it is necessary to transport, store and handle the appliance, only in vertical position,
respecting the indications on the packaging.

MAIN FEATURES

CONTENT OF THE PACKAGE AND OPTIONAL ACCESSORIES
n°1 Softner
n°1 Use and maintenance manual (this manual)
n°1 Transformer In – 230Vac Out 24Vac – 50/60Hz

FUNCTIONING PRINCIPLE

How softening happens:
Hard water is made to go through a layer of ions exchanger resins which properties withhold the encrusting salts
(calcium and magnesium) and replace them with others non-encrusting (sodium).
When the resins are saturate, wash them in a sodium chloride (food salt) solution to regenerate them. An inverted
exchange happens to previous, therefore, at the end of the operation, the resins will be ready again to supply more
softened water.
All this happens automatically.
SERVICE FLOW ((PARALLEL FLOW)
cod.W010771-rev.1
REGENERATION FLOW
(COUNTERFLOW)
Pag. 11