Hydraulic Connections; Technical Data; Installation And Commissioning - Gastrodomus AV8C Installation, Operating And Maintenance Manual

With automatic regeneration
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11
The equipment is controlled by an operational phases automatic valve:
1.
SERVICE
2.
F2 – BACKWASH RESIN
3.
F2 – BRINE AND SLOW RINSE
4.
F3 – BRINE FILL
5.
F4 – FAST RINSE

HYDRAULIC CONNECTIONS

Water connections: 3/4" BSP Male
Discharge: with hose-end fitting for hose with Ø 12 inside.
Brine: fitting for 3/8" hose

TECHNICAL DATA

Working pressure: min. 1.5bar – max. 6bar
Working water temperature: min. 2°C – max. 50°C
Electric power supply: 230Vac – 50Hz with output voltage from transformer at 24Vac
3
Maximum capacity: 1m

INSTALLATION AND COMMISSIONING

Installation must be carried out in compliance with the national standards in force, by professionally qualified and enabled
staff, following the Manufacturer instructions given in this manual.
An incorrect installation can cause damages to the environment, animals, persons and things, which the Manufacturer
cannot be considered responsible for.
OPENING THE PACKAGING
Open the box containing the valve with unsuitable tools can damage the appliance.
After having freed the valve from the packaging, check the integrity of the appliance. If in doubt or damaged, DO NOT
USE IT and contact the Distributor or Manufacturer. None of the packaging elements (bags, cardboard, expanded
polystyrene, claws, straps, etc.) must be left within children's reach as they are a potential source of danger.
PLACING THE PLANT AND CONNECTIONS
A comfortable placement is advantageous when having to carry out maintenance, any repairs and periodical loading of
the salt container.
The valve has been designed to work at an environmental temperature between 2°C and max. 40°C. Excessive heat and
frost seriously damage the appliance.
The automatic valve is electrically safe only when it is connected as foreseen by the national safety standards in force
and by professionally qualified and enabled staff.
The Manufacturer cannot be considered responsible for any damages caused by the non-compliance with the current
legislations.
cod.W010771-rev.1
/h (at 3bar)
Pag. 12
05/06/2021