4.1 Transporting the indoor unit

A pallet should be used for transportation to the final installa-
tion location.
Due to the high tare weight of the indoor unit, it should be
transported by means of a lift truck, hand truck, or similar. If this
is not possible, always transport the unit with several people.
When transporting the device, care must be taken not to dam-
age the unit, components and connections. Also protect the
device from moisture during transport.
The indoor unit tends to tip over when unfilled. Make sure that
it stands safely. If possible, the unit should always be trans-
ported upright.
CAUTION!
The indoor unit and transport pallet are connected together
with screws.
NOTE
The indoor unit must not be tilted by more than 45°.
4.2 Removing transport fastening
(depending on the device)
After transportation, the transport fastening in the device is to
be removed from the base.
CAUTION!
Please ensure that the transport fastening has been removed.
It causes unusual vibrations and noises at the heat pump if it is
operated with the transport fastening for the compressor in-
stalled.
www.dimplex.de
Remove
transport lock
LIA 1316BWCF
LIA 1316BWCF M
452172.66.10-EN · FD 0311
5

Installation

5.1 Indoor unit

The unit should always be installed indoors on a level, smooth
and horizontal surface. The indoor unit must be installed in a
way that allows maintenance work to be carried out from the
operator side without hindrance. This can be ensured by main-
taining a clearance of 1 m at the front. The space required (ap-
prox. 30 cm, see dimension drawing) for replacing the protec-
tive anode must be taken into consideration when determining
the required height of the installation room. It must be installed
in a room protected from frost and with short pipe runs.
CAUTION!
In an unfilled state (domestic hot water cylinder without
water), the device has a tendency to tilt in the direction of the
hydraulic assembly. Do not lean on the rear of the unit!
Setup and installation must be performed by an authorised
specialist company.
ca. / app. / env. 1m
Protection anode
Fig. 5.1: Indoor unit clearances
If the indoor unit is installed on an upper floor, the load-bearing
capacity of the ceiling should be checked. On account of the
acoustics, measures for isolating possible vibrations should
also be carefully planned in advance. Installation on floors
above wooden ceilings is not recommended.
The device should not be installed in rooms with high humidity
(e.g. shower rooms, wash rooms, etc.).
Furthermore, please note that the device has a tendency to tip
over when unfilled. Make sure that it is standing safely and re-
frain from leaning against the device or leaning objects against
the device.
CAUTION!
The installation room must meet the requirements for the
minimum installation space (see cap. 5.3).
CAUTION!
The device must be installed in a room with sufficient air
circulation.