LIA 0608BWCF M - LIA 1316BWCF M
3

Scope of supply

3.1 Indoor unit

Hydraulic components
Unmixed heating circuit including controlled circulating
pump
2. heat generator, electrical pipe heater, heat output 2 / 4 /
6 kW, secured via safety temperature limiter
Flow rate sensor
1.5 kW heating element
Three-way reversing valve
Cylinder (100 l and 300 l)
Overflow valve
Safety equipment:
Safety valve, start-to-leak pressure 3 bar
Refrigerating equipment
Heat exchanger refrigerant / heating water
Connections for split line
Electrical components
Heat pump manager with connection boards
Supply connection terminals and contactor, pipe heater
NOTE
External sensor is included with the outdoor unit as standard.
Connection of an external sensor is possible Cap. 9.5.2 on
page 29.
NOTE
An expansion vessel must be installed on-site.
www.dimplex.de

3.2 Heat pump manager

The integrated heat pump manager is a convenient electronic
regulating and control device. It controls and monitors the en-
tire heating system based on the outside temperature, as well
as domestic hot water preparation and safety systems.
The enclosed operating instructions describe the function and
use of the heat pump manager.