Figure 83. Installing the system battery
Next steps
1. Install the LOM riser card.
2. If applicable, connect the cables to the expansion card(s).
3. Follow the procedure listed in the
4. Confirm that the battery is operating properly, by performing the following steps:
a. Enter the System Setup, while booting, by pressing F2.
b. Enter the correct time and date in the System Setup Time and Date fields.
c. Exit the System Setup.
d. To test the newly installed battery, remove the system from the enclosure for at least an hour.
e. Reinstall the system into the enclosure after an hour.
f. Enter the System Setup and if the time and date are still incorrect, see
Optional internal USB memory key
NOTE:
To locate the internal USB port on the system board, see the
Replacing optional internal USB memory key
Prerequisites
CAUTION:
To avoid interference with other components in the server, the maximum permissible dimensions of
the USB memory key are 15.9 mm wide x 57.15 mm long x 7.9 mm high.
1. Follow the safety guidelines listed in the
2. Follow the procedure listed in the
3.
Remove the air
shroud.
Steps
1. Locate the USB port or USB memory key on the system board.
To locate the internal USB port on the system board, see the
2. If installed, remove the USB memory key from the USB port.
After working inside your
Safety
instructions.
Before working inside your
system.
Getting help
System board jumpers and connectors
system.
System board jumpers and connectors
Installing and removing system components
section.
section.
section.
85