Gree Versati III GRS-CQ4.0Pd/NhH2-E Owner's Manual page 43

Air-to-water heat pump split versati
Table of Contents

Advertisement

SPLIT
TYPE
Silk screen
AC-L
Live wire of power supply
N
Neutral wire of power supply
X3
To the ground
X20
E-heater of water tank
X21
E-heater 1
X22
E-heater 2
X23
Other thermal by 220VAC
X24
Reserved
X25
Reserved
X26
Reserved
X27
2-way valve 1 is normally open
X28
2-way valve 1 is normally closed
X29
Reserved
X30
Reserved
X31
Reserved
X32
Reserved
X33
Reserved
X34
3-way valve signal
CN18
Build-in water pump signal(PWM)
CN19
Back-up water pump signal(PWM)-field supply
CN15
20K temperature sensor (inlet water)
CN15
20K temperature sensor (outlet water)
CN15
20K temperature sensor (refrigerant liquid line)
CN16
20K temperature sensor (refrigerant vapor line)
CN16
10K temperature sensor (leaving water for the optional electric heater)
CN16
Rreserved
CN8
Remote room temperature sensor
CN9
Water tank temperature sensor
CN7
Rreserved
CN6
Rreserved
CN5
Rreserved
CN20
Thermostat
CN21
Detection to welding protection for the optional electric heater 1
CN22
Detection to welding protection for the optional electric heater 2
CN23
Detection to welding protection for the water tank electric heater
CN24
Gate-control detection
CN25
Flow switch
CN26
Reserved
CN3
Communication with outdoor unit
CN4
Communication with control panel
Air-to-water Heat Pump Split Versati
Introduction
39

Advertisement

Table of Contents
loading