Way Valve - Gree Versati III GRS-CQ4.0Pd/NhH2-E Owner's Manual

Air-to-water heat pump split versati
Table of Contents

Advertisement

SPLIT
TYPE

11. 2-Way Valve

The role of 2-way valve 1 is to control the water flow into the underfloor loop. When "Floor Config" is set to "With"
for either cooling or heating operation, it will keep open. When "Floor Config" is set to " Without", it will keep closed.
General Information
Type
NO 2-wire
NC 2-wire
(1) Normal Open type. When electric power is NOT supplied, the valve is open. (When electric power is
supplied, the valve is closed.)
(2) Normal Closed type. When electric power is NOT supplied, the valve is closed. (When electric power is
supplied, the valve is open.)
(3) How to Wire 2-Way Valve:
Follow steps below to wire the 2-way valve.
Step 1. Uncover the front cover of the unit and open the control box.
Step 2. Find the terminal block and connect wires as below.
• Normal Open type should be connected to wire (OFF) and wire (N) for valve closing in cooling mode.
• Normal Closed type should be connected to wire (ON) and wire (N) for valve closing in cooling mode.
(ON) : Line signal (for Normal Open type) from PCB to 2-way valve
(OFF) : Line signal (for Normal Closed type) from PCB to 2-way valve
(N) : Neutral signal from PCB to 2-way valve
12. 3-Way Valve
The 3-way valve 2 is required for the sanitary water tank. Its role is flow switching between the under floor
heating loop and the water tank heating loop.
General Information
Type
SPDT
230V 50Hz ~AC
3-wire
(1) SPDT = Single Pole Double Throw. Three wires consist of Live1 (for selecting Flow B), and Neutral (for
common).
(2) Flow A means 'water flow from the indoor unit to under floor water circuit'.
(3) Flow B means 'water flow from the indoor unit to sanitary water tank'.
Follow steps below to wire the 3-way valve:
Follow below procedures Step 1 ~ Step 2.
Step 1. Uncover front cover of the unit and open the control box.
Step 2. Find terminal block and connect wires as below.
Power
230V 50Hz ~AC
230V 50Hz ~AC
XT3
2-Way
Valve 1
Power
Selecting "Flow A" between "Flow A" and "Flow B"
Selecting "Flow B" between "Flow B" and "Flow A"
Air-to-water Heat Pump Split Versati
Operating mode
Closing water flow
Opening water flow
Closing water flow
Opening water flow
XT3
XT3
2-Way
2-Way
Valve 1
Valve 1
WARNING
Operating mode
29
Supported
Yes
Yes
Yes
Yes
Supported
Yes
Yes

Advertisement

Table of Contents
loading