Planet IPOE-470 User Manual page 10

Industrial 4-port 10/100/1ooot 802.3bt poe++ injector hub
Table of Contents

Advertisement

1. Insert positive and negative DC power wires into contacts 1 and 2 for
POWER 1, or contacts 5 and 6 for POWER 2.
2. Tighten the wire-clamp screws for preventing the wires from loosening.
PWR1 and PWR2 must provide the same DC voltage while
operating with dual power input.
The wire gauge for the terminal block should be in the range
between 12 and 24 AWG.
10
Max. Fault Alarm Loading: 24V, 1A
1 2 3 4 5 6
V1+
PWR1
Alarm
1
2
V1+
V1-
Power 1
Figure 5: PWR1 & PWR2 pins of terminal block.
V2+
DC Input:
PWR2
12-54V
, 6A max.
3
4
5
V2+
Alarm
Power 2
6
V2-