Vitus Audio Reference Series Owner's Manual

Integrated amplifier
Hide thumbs Also See for Reference Series:

Advertisement

Quick Links

REFERENCE
SERIES
RI–101 Mk.II
REFERENCE
INTEGRATED
AMPLIFIER
OWNER'S MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Reference Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vitus Audio Reference Series

  • Page 1 REFERENCE SERIES RI–101 Mk.II REFERENCE INTEGRATED AMPLIFIER OWNER’S MANUAL...
  • Page 2: Table Of Contents

    Mains supply voltage Mains fuse Introduction Fuse type About this manual Replacing a blown fuse 24-25 Introduction to the Reference Series Firmware updating 26-27 1. Getting started 5. Warranty What’s in the box, and how Warranty to correctly unpack it Heavy lifting –...
  • Page 3: From The Creator

    FROM THE CREATOR Foreword First of all, thank you for choosing the Vitus Audio RI-101 Mk.II Generally we’re after super neutral, super detailed and super dynamic Reference Integrated Amplifier, we are sure you will enjoy it for reproduction without “loosing” the nerve in the music which often is a drawback of many high end amplifiers.
  • Page 4: Introduction

    Introduction to the Reference Series This is your RI-101 Mk.II owner’s manual. The following pages will, Reference Series is your entry point to the world of Vitus Audio. as clearly as possible, describe how to get your RI-101 Mk.II operating The components in this series are cost-optimised versions of the quickly and easily.
  • Page 5: Getting Started

    1. GETTING STARTED 1. GETTING STARTED What’s in the box, and how RI-101 Mk.II device overview to correctly unpack it Gently cut open the tape on the top of the box, making sure to Box contents not let the knife protrude too much. Open the box and remove the foam top with all the included accessories.
  • Page 6: The Topology Of The Volume Control

    1. GETTING STARTED 2. CONNECTING The topology of the volume control Turning the RI-101 Mk.II on and off The topology of the volume control used in the RI-101 Mk.II is very To prevent pop in the output, we have chosen to first add the new Always turn on the products beginning from the source: different compared to the “standard”.
  • Page 7: Connecting The Ri-101Mk.ii

    2. CONNECTING 2. CONNECTING Connecting the RI-101Mk.II The rear panel Place the RI-101 Mk.II on its shelf. Connect all the sources Input 1 Input 2 Input 3 Input 3 Input 2 Input 1 to the inputs of the RI-101 Mk.II, PUSH PUSH PUSH...
  • Page 8: Operation

    3. OPERATION 3. OPERATION Operation modes Operation modes The RI-101 Mk.II has 3 operation modes 1. NORMAL This is the mode you use when listening to music. 2. MENU In this mode you can alter the settings of the RI-101 Mk.II. 3.
  • Page 9 3. OPERATION 3. OPERATION Functions Functions – left front panel – right front panel INPUT   INPUT   MENU SELECT MUTE MENU SELECT MUTE STANDBY STANDBY     Normal mode Menu mode Normal mode Menu mode In normal mode there are 3 basic functions/buttons available You enter menu mode, by pushing the “MENU”...
  • Page 10: The Elements In The Menu

    3. OPERATION 3. OPERATION The elements in the menu The elements in the menu You can modify the settings of your RI-101Mk.II by entering the menu and selecting the options you require. Refer to the menu structure diagram on page 21 for specific information.
  • Page 11: The Ri-101Mk.ii Menu Structure

    3. OPERATION 3. OPERATION The RI-101Mk.II menu structure MENU EXIT SETUP BACK EXIT PR/TAPE PREOUT TAPE REMOTE BACK EXIT ENA REM REM ON / REM OFF REMOTE ID DATA AutoStb o – 360 (min) RES. NO / RES. YES RESET V.INIT -80dB /+8dB BRIGHT...
  • Page 12: Operation And Service

    Mains fuse Fuse type: Vitus Audio products are designed to run for many years without Any unit may be set for operation in 100V, 115V, 230V or 240V AC. The mains fuse is accessible from the outside of the amplifier. You Physical size - 20 x 5mm the need for regular maintenance.
  • Page 13: Replacing A Blown Fuse

    4. OPERATION AND SERVICE 4. OPERATION AND SERVICE Replacing a blown fuse Replacing a blown fuse REMOVE THE POWER CABLE The fuse carrier is found on the back under the power Loosen the fuse carrier. Using a flat object for example Place the spare fuse in the fuse carrier and click the fuse connector.
  • Page 14: Firmware Updating

    4. Plug the power chord into the RI-101 Mk.II. You can contact your local Vitus Audio dealer if you are uncertain 5. The display will show “new FT detected” while updating (this takes about 5 seconds).
  • Page 15: Warranty

    XLR analogue RCA analogue Audio or an authorised Vitus Audio repair center by the customer damage to chassis parts. (See 6) at his or her sole expense. Vitus Audio will pay return freight of 3 (L+R) 2 (L+R) Available 2. CONDITIONS its choice.
  • Page 16: Examples Operation

    7. EXAMPLES OF OPERATION 7. EXAMPLES OF OPERATION Changing offset volume for inputs INPUT   MENU SELECT MUTE STANDBY   EXAMPLE 1 Changing offset volume for inputs A specific volume offset on the RI-101 Mk.II can be set on each individual input, to accomodate for different output levels of different sources.
  • Page 17: Changing Display Brightness

    7. EXAMPLES OF OPERATION 7. EXAMPLES OF OPERATION Changing display brightness Changing initial volume step INPUT   INPUT   MENU SELECT MUTE MENU SELECT MUTE STANDBY STANDBY     EXAMPLE 2 EXAMPLE 3 Changing display brightness Changing initial volume step The display on RI-101 Mk.II can be set to different brightness levels, You can set the volume step that the RI-101 Mk.II will initialise...
  • Page 18: Changing Input Names

    7. EXAMPLES OF OPERATION 7. EXAMPLES OF OPERATION Disabling inputs Changing input names INPUT   INPUT   MENU SELECT MUTE MENU SELECT MUTE STANDBY   STANDBY   EXAMPLE 4 EXAMPLE 5 Disabling inputs Changing input names Each individual input on the RI-101 Mk.II can be disabled in the menu.
  • Page 19: Setting Fixed Volume For Inputs

    7. EXAMPLES OF OPERATION 7. EXAMPLES OF OPERATION Setting fixed volume for inputs Configuring auto standby INPUT   INPUT   MENU SELECT MUTE MENU SELECT MUTE STANDBY   STANDBY   EXAMPLE 6 EXAMPLE 7 Setting fixed volume for inputs Configuring auto standby Each individual input on the RI-101 Mk.II can be set to a fixed volume The RI-101 Mk.II can be configured to automatically go into standby...
  • Page 20: Restore Factory Settings

    7. EXAMPLES OF OPERATION Restore factory settings INPUT   MENU SELECT MUTE STANDBY   EXAMPLE 8 Restore factory settings The RI-101 Mk.II can be restored to it’s factory settings if needed. YOU PRESS YOU SEE Press the “MENU” button to enter menu mode. Use the function buttons on the front of the unit to navigate to LINE 1 SETUP –...
  • Page 21: Ri-101 Mk.ii Owner's Manual

    HANDCRAFTED IN DENMARK AVA Group A/S (Vitus Audio) Hammershusvej 3H DK-7400 Herning Denmark Phone: +45 9626 8046 e-mail: sales@avagroup.nu Web: vitusaudio.com 40 | RI-101 Mk.II Owner’s manual...

This manual is also suitable for:

Ri-101 mk.ii

Table of Contents